Stuart Turner Ltd Approvals


#1910316

Range of booster sets consisting of two to four electronically controlled pumps which are connected in parallel and mounted on a common base provided with suction and discharge manifolds, spherical valves, expansion vessels and pressure gauge/transducers and non return valves. Cold water use only. Maximum working pressure 10 bar where the MTPA vessel is installed. 16 bar where the MTMB vessel is used.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
1910316
Expiry date:
31/10/2024
Size:
SP2V – 2” BSP(M) inlet x 1 ½” BSP(M) outlet SP3V – 2 ½” BSP(M) inlet x 1 ½” BSP(M) outlet SP4V – 3” BSP(M) inlet x 1 ½” BSP(M) outlet
Marking:
Model, year of manufacture YYYY, serial number and Fluid Water or Stuart Turner on adhesive label on rear of control panel
Installation Requirements:
R001 R415
Model:
Cold Water booster sets series SP2V, SP3V, SP4V (Horizontal pump version) Cold Water booster sets series SP2V, SP3V, SP4V (Vertical pump version) Where the following codes can be applied: SP = Product Range Name A = Number of Pumps (2,3 or 4 pumps) V = Variable Speed B = Pump Model (Horizontal or Vertical) C = Controller type (MAB-MARB) D = Power input (T = 3 Phase – M = 1Phase) E = Vessel Capacity (24= 1 of 24 litre Vessel), (48= 2 of 24 litre Vessels), (72= 3 of 24 litre Vessels), (96= 4 of 24 litre Vessels) Example: SP2V-5HM06S-MAB-T/24 SP = Product Range Name A = 2 Pumps V = Variable Speed B = 5HM06S C = MAB D = T – 3 Phase E = Vessel Capacity 24L
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
Unit 6 North Point Business Park Selby Road Eggborough East Yorkshire
Postcode
DN14 0JT
Phone
01977 801911
General Email
aquaboost@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2111366

Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2111366
Expiry date:
30/11/2026
Note:
These cisterns are not suitable for water for domestic purposes unless they are so modified and installed as to comply in all respects with Schedule 2. Section 7, Paragraph 4, of the Water Supply (Water Fittings) Regulations 1999. The products incorporate a Fluid Category 3 air gap arrangement.
Size:
1" BSP (M)
Marking:
Fluid Water or Stuart Turner, address, product ref, capacity, job ref and contact information on adhesive label on tank body. Fluid Water or Stuart Turner, model, year of manufacturer and serial no on control box.
Installation Requirements:
R001 R280 R415
Proviso:
If implemented, the overflow and warning pipe discharge to drain must be via a type `AA` `AB` or `AD` airgap in accordance with EN 1717.
Model:
IT-A-V-B-C-D-E-F-G-AG Where: IT = Product range name (In Tank). A = Number of pumps (1,2, or 3 pumps). V = Variable speed. B = Maximum flow (l/min per pump - 80 or 120l/min). C = Maximum head (m per Pump, e.g. 60). D = Controller type (MAB). E = Power input (T = 3 Phase – M = 1Phase). F = Vessel Capacity (8 = 8 litre, 24= 24 litre). G = Tank size (Nominal capacity in litres - 250-3000). AG = ‘AG’ air gap. Example: IT-3V-8060-MAB-M/24-1000-AG In Tank booster set with 3 pumps, variable speed, 80l/min max. flow and 60m max. head, MAB controller, 1 phase, 24 litre expansion vessel, 1000 litre capacity with an AG air gap.
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
Unit 6 North Point Business Park Selby Road Eggborough East Yorkshire
Postcode
DN14 0JT
Phone
01977 801911
General Email
aquaboost@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2111367

Range of cold water in tank booster sets incorporating an ‘AB’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2111367
Expiry date:
30/11/2026
Note:
These cisterns are not suitable for water for domestic purposes unless they are so modified and installed as to comply in all respects with Schedule 2. Section 7, Paragraph 4, of the Water Supply (Water Fittings) Regulations 1999. The products incorporate a Fluid Category 5 air gap arrangement.
Size:
1" BSP (M)
Marking:
Fluid Water or Stuart Turner, address, product ref, capacity, job ref and contact information on adhesive label on tank body. Fluid Water or Stuart Turner, model, year of manufacturer and serial no on control box.
Installation Requirements:
R001 R280 R415
Proviso:
If implemented, the warning pipe discharge to drain must be via a type `AA` `AB` or `AD` airgap in accordance with EN 1717.
Model:
IT-A-V-B-C-D-E-F-G-AB Where: IT = Product range name (In Tank). A = Number of pumps (1,2, or 3 pumps). V = Variable speed. B = Maximum flow (l/min per pump - 80 or 120l/min). C = Maximum head (m per Pump, e.g. 60). D = Controller type (MAB). E = Power input (T = 3 Phase – M = 1Phase). F = Vessel Capacity (8 = 8 litre, 24= 24 litre). G = Tank size (Nominal capacity in litres - 250-3000). AB = ‘AB’ air gap. Example: IT-3V-8060-MAB-M/24-1000-AB In Tank booster set with 3 pumps, variable speed, 80l/min max. flow and 60m max. head, MAB controller, 1 phase, 24 litre expansion vessel, 1000 litre capacity with an AB air gap.
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
Unit 6 North Point Business Park Selby Road Eggborough East Yorkshire
Postcode
DN14 0JT
Phone
01977 801911
General Email
aquaboost@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.