‘Fortes Aquaheat 540’ range of heat interface units (HIU) with twin stainless steel copper brazed plate heat exchangers providing space heating and instantaneous hot water. The hot water is generated via a plate heat exchanger. The cold inlet supply to the plate heat exchanger incorporates an in line single check valve assembly, (suitable for backflow protection against Fluid Category 2). The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 2.5 bar). The product is supplied with a filling loop comprising of an in-line double check valve assembly which incorporates an isolation valve (suitable for backflow protection against Fluid Category 3), a stainless steel braided EPDM lined flexible hose assembly and a separate isolation valve. The inlet and outlet of all circuits incorporates a lever operated spherical valve with a brushed chromium plated brass body. Maximum working pressures and operating temperatures: Primary (district heating): 16.0 bar and 100˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.0 bar and 95˚C.
Page of 1
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.