Cosmogas Srl Approvals


#1907322

Range of gas fired instantaneous condensing domestic hot water heaters with integral storage tank. Having a stainless-steel coil and built in circulating pump. Maximum working pressure 11.0 bar. Maximum operating temperature 80°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1907322
Expiry date:
31/07/2024
Size:
1½” BSP (M)
Marking:
Cosmogas on front casing. Cosmogas, production date (YYYY) and other technical information on adhesive label on side of body
Installation Requirements:
R001 R140
Model:
Aguaplus 60, 70, 100, 115, 140
Manufacturer:
Cosmogas Srl
Company Name
Cosmogas Srl
Address

View All Listings by this Company

Print This Approval


#1909361

Aguadens range of direct fired, gas condensing water heaters with stainless steel tubes and EPDM ‘O’-rings. The products incorporate a drain tap. Maximum operating pressure 11.0 bar. Maximum operating temperature 60˚C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
1909361
Expiry date:
30/09/2024
Size:
60T, 70T, 100T, 115T, 140T models: 2” NPT (M). 180T, 210T, 280T models: 2½” NPT (M).
Marking:
Cosomgas on front of body
Installation Requirements:
R001 R140 R511
Model:
Aguadens 60T, 70T, 100T, 115T, 140T, 180T, 210T & 280T.
Manufacturer:
Cosmogas Srl
Company Name
Cosmogas Srl
Address

View All Listings by this Company

Print This Approval


#1910339

Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system.Incorporating a pressure relief valve set at 3.0 bar and an expansion vessel. Maximum working pressure of 2.5 bar (primary) & 7.0 bar (secondary). Cold supply only. Maximum operating temperature 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1910339
Expiry date:
31/10/2024
Size:
Secondary – inlet ½” BSP(M) & 15mm copper tail outlet. Primary – 22mm copper tail.
Marking:
Cosmogas on front of boiler.
Installation Requirements:
R001 R360
Proviso:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
Mydens 34P, Q30P & Mydens 24P
Manufacturer:
Cosmogas Srl
Company Name
Cosmogas Srl
Address

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.