Navigator MSL Ltd. Approvals


#2109065

Range of single check valve assemblies with DZR brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
0030 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type EB - Non verifiable single check valve.
WRAS Approval Number:
2109065
Expiry date:
30/09/2026
Size:
15mm - CMBFSCV-15, 22mm - CMBFSCV-22 or 28mm -CMBFSCV-28 Compression
Marking:
MID, CR, size, PN and flow arrow on body.
Installation Requirements:
R001
Model:
CMBFSCV-15, CMBFSCV-22 & CMBFSCV-28
Factor:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval


#2001154

Range of non-verifiable double check valve assemblies, incorporating two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies. The products incorporate a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2001154
Expiry date:
31/01/2025
Note:
Not for use with water injected with CO2 gas.
Size:
see model
Marking:
MID (Tradename of Midbrass), size, flow arrow and CR marking on body. EN1245-2 on compression nuts.
Installation Requirements:
R001
Model:
MBFDCV-15W* - 15mm compression. CMBFDCV-15* (Nickel plated) - 15mm compression. MBFDCV-22W* & CMBFDCV-22* - 22mm compression. CMBFDCV-28* - 28mm compression.
Factor:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval


#2005054

Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2005054
Expiry date:
31/05/2025
Note:
Not for use with water injected with CO2 gas.
Size:
See model.
Marking:
MSL, WRAS, size, CR, date of manufacture MM/YY and flow arrow on body.
Installation Requirements:
R001
Model:
BFDCV-15 & TBFDCV-15 - 15mm compression inlet/outlet BFDCV-22 & TBFDCV-22 - 22mm compression inlet/outlet
Factor:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval


#2010420

Range of non-verifiable double check valve assemblies with DZR brass bodies, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2010420
Expiry date:
31/10/2025
Size:
See model.
Marking:
MSL, WRAS, size, CR, date of manufacture MM/YY and flow arrow on body.
Installation Requirements:
R001
Model:
BFDCV-28 – 28mm compression
Factor:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval


#2201101

Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The CMBHUBDC-D model incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201101
Expiry date:
31/01/2027
Size:
½” BSP (M).
Marking:
CMBFHUB-D Model MID and size on body. CMBHUBDC-D, CR and size on body.
Installation Requirements:
R001 R040
Model:
Brass body: CMBFHUB-D DZR brass body: CMBHUBDC-D
Factor:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 5

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.