Deck mounted two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) with a self-cancelling diverter to a shower outlet. The product incorporates a ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts, stainless steel braided PVC lined shower hose and chromium plated shower handset. Maximum operating pressure 5 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets and shower kits with chromium plated ABS bodies. Some models incorporate a shower hose.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps, (chrome plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a flow straightener. Maximum working pressure 10 bar. Maximum operating temperature 45 C.
Combined bath filler and overflow waste assembly with plastic bodies (various finishes).The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product incorporates click type pop-up waste (verified by test). Open outlet use only. For domestic use IRN R160 applies. For non-domestic use IRN R090 applies. Maximum operating temperature 45°C.
T-type thermostatic mixing valve with a brass body. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless steel strainers. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Range of wall mounted, thermostatic blending shower valves, incorporating a quarter turn ceramic disc headworks or ceramic disc diverter cartridges (see models) with a cube type operating members. The temperature is controlled independently via a thermostatic cartridge with a cube type operating members that incorporate manual override buttons. Model (1.1901.001) is supplied with a shower hose, hanset & riser rail assemblies. Model (1.1901.002) is supplied with a shower hose, handset, overhead shower & riser rail assebmlies. The inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 10 bar. Maximum operating temperature 45°C
Non-metallic materials and components comply with BS6920 at 45°C
Range of wall mounted exposed and concealed thermostatic shower valves, chrome plated brass body or brass bodies with chrome trim sets). Incorporating a single sequential headwork controlling both flow and temperature with single lever operating members. The inlets incorporate plastic flow regulators. Model (1.1656.011) is supplied with a shower hose, handet and riser rail assembly. Model (1.1656.012) is supplied with a wall mounted shower outlet, hose, handset and riser rail assembly. Model (1.1656.013) is supplied with a wall mounted shower arm and an overhead shower. Maximum operating pressure 5 bar. Maximum operating temperature 65°C
Range of wall mounted, concealed or exposed (see models) thermostatic shower valves (chromium plated brass), incorporating a ceramic disc headwork controlling the flow and an independent thermostatic cartridge controlling the temperature, both with single lever type operating members. The temperature control incorporates a manual override. The inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted concealed and exposed thermostatic shower valves, (chrome plated brass bodies or chrome trim sets), incorporating single sequential headworks controlling both the flow and temperature. The inlets incorporate single check valve cartridges, however, the complete products have not been fully tested to demonstrate it provides backflow protection. Products are supplied with flow regulators. Maximum operating pressure 5.0 bar. Maximum operating temperature 50°C
Range of MIRA MODE high pressure or pumped, wall fed or ceiling fed bath/shower mixing valves supplied with overhead shower and shower handsets. Inlets are supplied with isolation valves. Maximum working pressure 5 bar for high pressure models and 1 bar for pumped models. Non-metallic materials and components comply with BS6920 at 48°C.
Range of shower outlets with plastic bodies available in white or chromium finishes. Model 2.1605.154 (1867.012) is supplied with a shower hose. Open outlet use only. Maximum operating temperature 55°C.
Range of quarter turn ceramic disc headworks with brass bodies, intended for insertion into specifically dimensioned tap assemblies. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of shower handsets with either a white or chrome plated plastic body. Maximum operating temperature 45°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome type operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of bath pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and cross top operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 10 Bar. Maximum operating temperature 60°C.
‘Rada’ electronically controlled thermostatic blending valve, with a stainless-steel body, EPDM ‘o’ rings and seals. Maximum working pressure; 13.8 Bar. Maximum operating temperature 85°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves, (brass bodies – chrome plated plastic trim sets) incorporating single sequential headworks controlling both flow and temperature. The inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate back flow protection. Model (31997W is valve only) all other models are supplied with shower hose, handset & riser rail assembly. Maximum operating pressure 5 bar. Maximum operating temperature 50°C
ange of wall mounted thermostatic shower valves, (brass bodies – chrome plated plastic trim sets). Incorporating a sequential headwork controlling flow and temperature. Model (31983W-CP) direction of flow is controlled independently with a single lever operating member that diverters from shower to shower. Model (31982W-CP) is supplied with a shower hose, handset & riser rail assembly. Model (31983W-CP) is supplied with a shower hose, handset, over head shower & riser rail assembly. Maximum operating pressure 5 bar. Maximum operating temperature 50°C
Range of electric instantaneous heated showers, incorporating a solenoid valve to control the flow. Products are supplied with a shower hose and handset. Maximum supply pressure 10 bar. Maximum operating temperature 45°C.
Range of wall mounted thermostatic shower valves, (chrome plated brass bodies), incorporating a quarter turn ceramic disc headworks with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Model (1.1660.007) incorporates an overhead shower and riser rail assembly. Model (1.1660.015) incorporates a shower hose, handset, overhead shower, riser rail assembly and a shower to shower diverter. Maximum operating pressure 5 bar. Maximum operating temperature 65°C
Range of flexible shower hose assemblies comprising of a PVC inner, multi-layered hose (silver external appearance), with silicone ‘O’-rings and washers. Maximum operating temperature: 60°C. Open Outlet use only.
Shower wastewater heat recovery units with a copper body and twin wall separation. Maximum working pressure 10.0 Bar. Maximum operating temperature 45°C.
Page 3 of 3
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.