#1903307

Range of undercounter commercial dishwashing machines, flow is controlled via solenoid valve that discharges via a Type ‘AA’ air gap. The machine incorporates a salt regenerated water softener. Maximum working pressure 4.0 Bar. Cold water only

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
1903307
Expiry date:
31/03/2024
Size:
¾” BSP Captive nut.
Marking:
Fagor and Fagor logo on front of machine. Fagor and other technical information on data plate.
Installation Requirements:
R001 R160
Model:
E-VO ADVANCE AD-505 SOFT
Manufacturer:
Fagor Industrial S Coop.
Company Name
Fagor Industrial S Coop.
Address
Barrio Sancholopetegui 22 20560 - Oñati
Country
Spain
Phone
+34 943 71 80 30

View All Listings by this Company

Print This Approval


#1903341

Range of hood type commercial dishwashing machines. Flow is controlled via solenoid valve and discharges via a Type ‘AA’ air gap. The machines with ‘SOFT’ in the model incorporate a salt regenerated water softener. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
1903341
Expiry date:
31/03/2024
Note:
This appliance incorporates a Fluid Category 5 backflow prevention device.
Size:
PVC lined flexible hose assembly with ¾” captive nut end connections
Marking:
Fagor on front. Adhesive label on lower panel with Fagor, model & technical information.
Installation Requirements:
R001 R009 R160
Model:
E-VO CONCEPT+ COP-144 H E-VO CONCEPT+ COP-144 H B E-VO CONCEPT+ COP-144 H DD E-VO CONCEPT+ COP-144 H B DD E-VO CONCEPT+ COP-144 H HRS E-VO CONCEPT+ COP-144 H HRS B E-VO CONCEPT+ COP-144 H HRS B DD E-VO CONCEPT+ COP-144 H HRS DD E-VO CONCEPT+ COP-174 H E-VO CONCEPT+ COP-174 H B E-VO CONCEPT+ COP-174 H DD E-VO CONCEPT+ COP-174 H B DD E-VO CONCEPT+ COP-174 H HRS E-VO CONCEPT+ COP-174 H HRS B E-VO CONCEPT+ COP-174 H HRS B DD E-VO CONCEPT+ COP-174 H HRS DD E-VO ADVANCE AD-125 H E-VO ADVANCE AD-125 H AU E-VO ADVANCE AD-125 H HRS AU E-VO ADVANCE AD-125 H HRS E-VO ADVANCE AD-125 H HRS SOFT E-VO ADVANCE AD-125 H SOFT
Manufacturer:
Fagor Industrial S Coop.
Company Name
Fagor Industrial S Coop.
Address
Barrio Sancholopetegui 22 20560 - Oñati
Country
Spain
Phone
+34 943 71 80 30

View All Listings by this Company

Print This Approval


#1903088

Range of front loading commercial dishwashers with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 Bar. Maximum operating temperature 60°C.

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
1903088
Expiry date:
31/03/2024
Note:
This appliance incorporates a Fluid Category 5 backflow prevention device.
Size:
Stainless steel braided EPDM lined flexible hose assembly with ¾” captive nut end connections.
Marking:
DC Products, DC Products logo, model, operating info on label on right side panel. DC series on door handle
Installation Requirements:
R001 R574
Model:
SD40A, SD45A, SD50A, SXD45A, SXD50A. ED50A. PG/PD40A, PG/PD45A, PG/PD50A. OG/OD40A, OG/OD50A. DC1500A, DC1650A, DC2000A, DC3000A, DC4600A. X600A, X700A. W700A, W1100A, W1400A, W1400SA. SD900A. PD1000A, PD1300A, PD1350A. OD1400A, OD1425A, OD1450A. DCF2500A, DCF3500A, DCF5000A. DC57-42A, DC57-62A. DC67A, DC109A.
Factor:
DC Products Ltd
Company Name
DC Products Ltd
Address
Unit 25 lodge hill Industrial Park Westbury Sub Mendip Somerset
Postcode
BA5 1EY

View All Listings by this Company

Print This Approval


#1906093

Range of commercial dishwashers. Flow is controlled by a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). E ES models incorporate a heat recovery system and a double check valve assembly. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
1906093
Expiry date:
30/06/2024
Note:
These appliances incorporate Fluid Category 5 backflow protection. This approval is for the dishwasher and the components listed in the description and doesn’t include any accessories, e.g. booster pump.
Size:
¾” captive nut
Marking:
Aristarco models - Aristarco on front panel. Kastel models – Kastel on front panel. Models without brand: Aristarco, model, product info on label on side panel. No marking on front panel.
Installation Requirements:
R001 R009 R574
Model:
Aristarco brand: AF 40.30, AF 45.30, AF 50.35, AF 50.35 H, AF 60.40, AS 40.30, AS 45.30, AS 50.35, AS 60.40, AL 40.30, AL 50.35, AH 800, AH 1040, AH 1240, AH 800 E ES, AH 1040 E ES, AH 1240 E ES. AU 60-40, AU 60-45, AU 60-42, AU 55-65, AU 55-80, AU 65-65, AU 125-80, AU 55-65 E ES, AU 55-80 E ES, AU 65-65 E ES, AU 125-80 E ES. Kastel brand: FK 40, FK 45, FK 50, FK 50 H, FK 60/40, SK 40, SK 45, SK 50, SK 60/40, LK 40, LK 50, HK 850, HK 1200, HK 1500, HK 850 E ES, HK 1200 E ES, HK 1500 E ES, UK 60/40, UK 60/45, UK 60/42, UK55/65, UK 55/80, UK 65/65, UK 125/80, UK 55/65 E ES, UK 55/80 E ES, UK 65/65 E ES, UK 125/80 E ES. Models without brand: EF 40, EF 45, EF 50, EF 50 H, EF60/40, ES 40, ES 45, ES 50, ES 60/40, EL 40, EL 50, EH 850, EH 1200, EH 1500, EH 850 E ES, EH 1200 E ES, EH 1500 E ES, EU 60/40, EU 60/45, EU 60/42, EU 55/65, EU 55/80, EU 65/65, EU 125/80, EU 55/65 E ES, EU 55/80 E ES, EU 65/65 E ES, EU 125/80 E ES
Manufacturer:
Aristarco S.p.A.
Company Name
Aristarco S.p.A.
Address

View All Listings by this Company

Print This Approval


#1907005

Range of commercial dish washing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
1907005
Expiry date:
31/07/2024
Size:
¾” BSP captive nut
Marking:
Eurotec, Colged logo, model & technical information on label on side panel
Installation Requirements:
R001 R574
Model:
TopTech 34-23D, 35-23D, 36-23D, 36L-23D, 38-23D & 39-23D
Manufacturer:
Eurotec Srl div Colged
Company Name
Eurotec Srl div Colged
Address
Via Provinciale Romana 6-55010 Badia Pozzeveri Italy

View All Listings by this Company

Print This Approval


#1909030

Range of under counter and hood type dishwashing machines with flow controlled by solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). There is a double check valve supplied with every machine. Some models are available with AirConcept and GiO-Module options. Maximum working pressure 5.0 Bar. Models incorporating AirConcept & GiO-Module are cold water use only. All other models have a maximum operating temperature 60°C. Modification November 2019 Supplied with Airbreak to drain.

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
1909030
Expiry date:
30/09/2024
Note:
IRN’s R415 & R510 apply to products which incorporate the GiO-Modules reverse osmosis unit. This appliance incorporates a Fluid Category 5 backflow prevention device. The product is supplied with a double check valve for use on the inlet. At least a single check valve is required on each supply to this fitting because it is for a non-wholesome water application so the materials of construction have not been fully assessed against the requirements of the Regulations. The double check valve supplied with this product must be installed to maintain the validity of the WRAS approval.
Size:
¾” BSP captive nut (to inlet hose)
Marking:
Meiko, UPster on control panel. Meiko, model, product info on adhesive label on side panel.
Installation Requirements:
R001 R415 R510 R574
Model:
U M2 - Series undercounter dishwashing machines: UPster U 400, UPster U 500G, UPster U 500, TopClean 60 & TopClean M. All undercounter models except UPster U 400 can be supplied with GiO-Module. H M2 - Series hood type dishwashing machines: UPster H 500 which can be supplied with AirConcept & GiO-Module.
Factor:
MEIKO Maschinenbau GmbH & Co. KG
Company Name
MEIKO Maschinenbau GmbH & Co. KG
Address
Englertr 3 77652 Offenburg Germany

View All Listings by this Company
Manufacturer:
MEIKO Maschinenbau GmbH & Co. KG
Company Name
MEIKO Maschinenbau GmbH & Co. KG
Address
Englertr 3 77652 Offenburg Germany

View All Listings by this Company

Print This Approval


#2001345

Range of conveyor type commercial dishwashing machines. Flow is controlled via solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The product incorporates a nylon bodied inline strainer with a stainless steel screen as the inlet to the machine. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2001345
Expiry date:
31/01/2025
Size:
¾” BSP(M)
Marking:
Fagor (manufacturer) address, model no, ref no, serial no and other techcnial information on side panel. Fagor, concept on front panel.
Installation Requirements:
R001 R160 R574
Model:
CCO-120 AG CW I. CCO-120 AG CW D. CCO-120 AG HW I. CCO-120 AG HW D. CCO-160 AG CW I. CCO-160 AG CW D. CCO-160 AG HW I. CCO-160 AG HW D. Where: “AG” stand for: AIR GAP. “CW” stand for: COLD WATER. “HW” stand for: HOT WATER. “I” stand for: CONVEYOR BELT- INLET OF BASKET FROM LEFT. “D” stand for : CONVEYOR BELT- INLET OF BASKET FROM RIGHT.
Manufacturer:
Fagor Industrial S Coop.
Company Name
Fagor Industrial S Coop.
Address
Barrio Sancholopetegui 22 20560 - Oñati
Country
Spain
Phone
+34 943 71 80 30

View All Listings by this Company

Print This Approval


#2001101

Range of commercial dishwashers, glass washers and washer disinfectors, with solenoid valves incorporating a plastic strainer and plastic flow regulator controlling the flow and discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5), one on the cold water supply and hot water supply lines to the washing system and another as part of the steam condenser circuit (applicable models). The appliances are available with or without a water softener (ion exchange), steam condenser and additional water supply. The products are supplied with ¾” BSP (F) x ¾” BSP (M) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet and optional ¾” BSP (M) x ¾” BSP (F) in-line strainers (incorporating a stainless steel mesh) to be installed after the double check valve assembly. Models with a steam condenser circuit include a ‘Y’-piece connector ¾” BSP (F) inlet x ¾” BSP (M) outlets to install after the double check valve or filter (if fitted) prior to the inlet hoses. Maximum working pressure 10.0 Bar. Maximum operating temperature of product and hot supply 60°C. All other inlets are cold supply only.

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2001101
Expiry date:
31/01/2025
Note:
These appliances incorporate Fluid Category 5 backflow protection. The double check valves supplied with this product must be installed on all available inlets to maintain the validity of the WRAS approval. Discharge to drain must be via a type AA, AB or AD air gap or in accordance with EN1717.
Size:
¾” BSP captive nut (supply hose)
Marking:
Miele on control panel. Miele, model and product info on label on rear panel. Miele, model and product info on label inside of door.
Installation Requirements:
R001 R574
Model:
Water softener (only) models: PG8504, PG8055, PG8056, Water softener and steam condenser models: PG8056U, PG8058, PG8059, PG8581, PG8582, PG8582CD, PG8583, PG8583CD, PG8591, PG8593.
Factor:
Miele Company Ltd.
Company Name
Miele Company Ltd.
Address
Fairacres Marcham Road Adington
Postcode
OX14 1TW

View All Listings by this Company
Manufacturer:
Miele & Cie. KG
Company Name
Miele & Cie. KG

View All Listings by this Company

Print This Approval


#2003381

Range of pass through commercial dishwashing machines (with a water softener - RA models, or without - R models). Flow is controlled by a solenoid valve, which incorporates a flow restrictor and a strainer, and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). . The water softener (where fitted) is located downstream of the ‘AB’ air gap. The product is supplied with a grey nylon braided EPDM lined flexible hose assembly with ¾” captive nut end connections incorporating EPDM washers. Maximum working pressure 4.0 bar. Maximum operating temperature 60°C.

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2003381
Expiry date:
31/03/2025
Note:
This appliance incorporates a Fluid Category 5 backflow prevention device. Claims for flow rate are made by the manufacturer and not considered part of the listing.
Size:
¾” BSP (F) captive nut (to inlet hose).
Marking:
Comenda prime on front casing. Comenda, model, serial no., which includes date of manufacture (MMYY) as the final four digits and other technical information on adhesive label on side of unit.
Installation Requirements:
R001 R009 R520 R574
Model:
PC07 R, PC07 RA, PC09 R, PC09 RA, PC12 R, PC12 RA, HC10 R, HC10 RA, HC14 R, HC14 RA, PCXL R, PCXL RA, HCXL R & HCXL R.
Manufacturer:
COMENDA ALI GROUP SRL
Company Name
COMENDA ALI GROUP SRL
Address
VIA GALILEO GALILEI, 8 20060 CASSINA DE PECCHI MILAN
Country
ITALY

View All Listings by this Company

Print This Approval


#2001121

Range of commercial dishwashers, glass washers and washer disinfectors, with solenoid valves incorporating a plastic strainer and plastic flow regulator controlling the flow and discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5), one on the cold water supply and hot water supply lines to the washing system and another as part of the steam condenser circuit (applicable models). The appliances are available with or without a water softener (ion exchange), steam condenser and additional water supply. The products are supplied with ¾” BSP (F) x ¾” BSP (M) double check valve assemblies (suitable for backflow protection against Fluid Category 3) for installation on each inlet and optional ¾” BSP (M) x ¾” BSP (F) in-line strainers (incorporating a stainless steel mesh) to be installed after the double check valve assembly. Models with a steam condenser circuit include a ‘Y’-piece connector ¾” BSP (F) inlet x ¾” BSP (M) outlets to install after the double check valve or filter (if fitted) prior to the inlet hoses. Maximum working pressure 10.0 Bar. Maximum operating temperature of product and hot supply 60°C. All other inlets are cold supply only.

Section:
2390 Washing Machines
Section Subtitle:
Dish. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2001121
Expiry date:
31/01/2025
Note:
These appliances incorporate Fluid Category 5 backflow protection. The double check valves supplied with this product must be installed on all available inlets to maintain the validity of the WRAS approval. Discharge to drain must be via a type AA, AB or AD air gap or in accordance with EN1717.
Size:
¾” BSP captive nut (supply hose)
Marking:
W & H ON CONTROL PANEL MODEL, PRODUCT INFORMATION ON LABEL ON REAR PANEL & INSIDE OF DOOR
Installation Requirements:
R001 R574
Model:
RID 100 & RID 200
Factor:
W&H Sterilization Srl
Company Name
W&H Sterilization Srl

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.