Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#1904032

Range of hot water buffer tanks consisting of insulated stainless steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1904032
Expiry date:
30/04/2024
Size:
1500-3000 litre
Marking:
“Lapesa”, model number & technical information on adhesive label.
Installation Requirements:
R001 R511
Model:
MASTER INOX Range: MXM-RB-3000-PSS [3" male BSP inlet and outlet], MXM-RB-3000-PSS2 [2" male BSP inlet and outlet], MXM-RB-3000 [2" male BSP inlet and outlet], MXM-RB-2500-PSS [3" male BSP inlet and outlet], MXM-RB-2500-PSS2 [2" male BSP inlet and outlet], MXM-RB-2500 [2" male BSP inlet and outlet], MXM-RB-2000-PSS [3" male BSP inlet and outlet], MXM-RB-2000-PSS2 [2" male BSP inlet and outlet], MXM-RB-2000 [2" male BSP inlet and outlet], MXM-RB-1500-PSS [3" male BSP inlet and outlet], MXM-RB-1500-PSS2 [2" male BSP inlet and outlet] & MXM-RB-1500 [2" male BSP inlet and outlet].
Factor:
Mitsubishi Heavy Industries Ltd
Company Name
Mitsubishi Heavy Industries Ltd
Address
3-1 Asahi Nishibiwajima-Cho Kiyosu
Country
Aichi

View All Listings by this Company
Manufacturer:
Lapesa
Company Name
Lapesa
Address
Poligono Industrial de Malpica Calle A Percel 1-B
Country
50057 Zaragoza
Phone
+34 976 465 180

View All Listings by this Company

Print This Approval


#1904351

Range of free standing unvented vitreous enamel lined carbon steel buffer vessels. The vessels are supplied with a sacrificial magnesium anode. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1904351
Expiry date:
31/12/2024
Size:
See model
Marking:
Andrews Water heaters (brand of Baxi), manufacturer’s address, model, serial no., year of manufacture (YYYY), max. pressure, capacity and other technical information on adhesive label on body. on body
Installation Requirements:
R001 R140
Model:
Buffer GL300-10 – inlet 1” BSP (M). Buffer GL500-10 – inlet 1” BSP (M). Buffer GL800-10 – inlet 1¼” BSP (M).
Factor:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company

Print This Approval


#1904352

Range of free standing unvented vitreous enamel lined carbon steel buffer vessels. The vessels are supplied with a sacrificial magnesium anode. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1904352
Expiry date:
30/04/2024
Size:
See model
Marking:
Andrews Water heaters (brand of Baxi), manufacturer’s address, model, serial no., year of manufacture (YYYY), max. pressure, capacity and other technical information on adhesive label on body. on body
Installation Requirements:
R001 R140
Model:
Buffer GL200-8 – inlet 1” BSP (M). Buffer GL300-8 – inlet 1” BSP (M). Buffer GL500-8 – inlet 1” BSP (M). Buffer GL800-8 – Inlet 1” BSP (M). Buffer GL1000-8 – Inlet 1” BSP (M).
Factor:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company

Print This Approval


#1905073

Mixergy MX range of stainless steel direct and indirect, single and dual coil, hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C and a safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and an expansion vessel is also supplied. Maximum working pressure secondary circuit 5.5 bar Maximum operating pressure primary coils 3.5 bar Maximum operating temperature 70˚C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1905073
Expiry date:
31/05/2024
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre.
Marking:
Mixergy and technical information (including pressure) on adhesive label on body.
Installation Requirements:
R001 R140 R360
Model:
Mixergy MX xxx ELE-EXT w-w-x-y-zz Direct, Unvented, External Expansion, Hot Water Storage Cylinders, 90-300 Litre capacity. Mixergy MX xxx IDE EXT w-w-x-y-zz Indirect Unvented, External Expansion,Hot Water Storage Cylinders, 150-300 Litre capacity. Mixergy MX xxx Duo EXT w-w-x-y-zz Indirect Dual Coil, Unvented, External Expansion, Hot Water Storage Cylinders,210-300 Litre capacity. Where: xxx=Tank capacity (litres): 90,120,150,180,210,250,300 EXT= defines the expansion vessel as external to the cylinder. W=Diameter 475,550,690 W= Main immersion 1- Single element - 2 dual element (for PV diverter use). X = lower immersion: 0- not fitted, 1 with back up immersion. Y = Controller: A – Industrial (DIN rail), B – Domestic (PCB). Only affects type of external electronic controller used. zz= Options: 00 – none, 01 – PV diverter switch. Only affects electronic controller options.
Factor:
Mixergy Ltd.
Company Name
Mixergy Ltd.
Address
2 Canal View Wharf Farm Eynsham
Postcode
OX29 4DB
Country
Oxfordshire

View All Listings by this Company
Manufacturer:
RM Cylinders
Company Name
RM Cylinders
Address
4 Valencia Park, Gilcar Way, Wakefield Europort
Postcode
WF10 5QS
Country
West Yorkshire

View All Listings by this Company

Print This Approval


#1906091

Range of hot water buffer tanks consisting of insulated enamel vitrified carbon steel shells. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1906091
Expiry date:
30/06/2024
Size:
500-1000 litre
Marking:
‘Lapesa’ & model on adhesive label.
Installation Requirements:
R001 R511
Model:
CORAL VITRO Range: CVM-RB-1000/PSS [3" male BSP inlet and outlet]. CVM-RB-1000/PSS2 [2" male BSP inlet and outlet]. CVM-RB-1000 [2" male BSP inlet and outlet]. CVM-RB-750/PSS [3" male BSP inlet and outlet]. CVM-RB-750/PSS2 [2" male BSP inlet and outlet]. CVM-RB-750 [2" male BSP inlet and outlet]. CVM-R-750/PSS [3" male BSP inlet and outlet]. CVM-R-750/PSS2 [2" male BSP inlet and outlet]. CVM-R-750 [2" male BSP inlet and outlet]. CVM-R-500/PSS [3" male BSP inlet and outlet]. CVM-R-500/PSS2 [2" male BSP inlet and outlet]. CVM-R-500 [2" male BSP inlet and outlet].
Factor:
Mitsubishi Heavy Industries Air-conditioning Europe Limited
Company Name
Mitsubishi Heavy Industries Air-conditioning Europe Limited
Address

View All Listings by this Company
Manufacturer:
Lapesa Grupo Empresarial S. L.
Company Name
Lapesa Grupo Empresarial S. L.
Address

View All Listings by this Company

Print This Approval


#1907057

Solar twin coil range of stainless steel indirect hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish, expansion vessel and a drain valve also comes supplied. Maximum operating pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 3.0 bar. Maximum operating pressure solar circuit 5.5 bar. Maximum operating temperature 65˚C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1907057
Expiry date:
31/07/2024
Size:
25 litre, 90 litre, 150 litre, 170 litre, 200 litre, 250 litre, 300 litre
Marking:
Telford, model, pressure, capacity and technical info on adhesive label on body
Installation Requirements:
R001 R140 R530 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20OC and 45 OC. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
ornado Direct 3.0 90 litre Tornado Direct 3.0 125 litre Tornado Direct 3.0 150 litre Tornado Direct 3.0 170 litre Tornado Direct 3.0 200 litre Tornado Direct 3.0 250 litre Tornado Direct 3.0 300 litre Tornado Indirect 3.0 90 litre Tornado Indirect 3.0 90 litre Tornado Indirect 3.0 125 litre Tornado Indirect 3.0 150 litre Tornado Indirect 3.0 170 litre Tornado Indirect 3.0 200 litre Tornado Indirect 3.0 250 litre Tornado Indirect 3.0 300 litre Tornado twin coil 3.0 170 litre Tornado twin coil 3.0 200 litre Tornado twin coil 3.0 250 litre Tornado twin coil 3.0 300 litre
Factor:
Telford Copper and Stainless Ltd.
Company Name
Telford Copper and Stainless Ltd.
Address
Furrows Business Park Haybridge Road Wellington
Postcode
TF1 2DF
Country
Telford

View All Listings by this Company
Manufacturer:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval


#1909074

Mitsubishi EHPT20X-MHEDW indirectly heated stainless-steel storage cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. The product is supplied with a safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, a pressure relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar. The product is also supplied with a tundish, an expansion vessel and a filling loop assembly, consisting of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly (suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve. Maximum working pressure secondary circuit 5.5 bar. Maximum working pressure primary circuit 2.5 bar. Maximum operating temperature 70°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909074
Expiry date:
30/09/2024
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
200 Litre – 22m compression
Marking:
Mitsubishi, model, technical info including pressures and capacity on adhesive label on top of unit.
Installation Requirements:
R001 R140 R360
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
EHPT20X-MHEDW
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#1909091

STELFLOW range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909091
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre, 350 litre, 400 litre, 450 litre, 500 litre.
Marking:
Stelflow and RM Cylinders on cylinder. RM Cylinders and technical information including pressures and capacity on adhesive label on cylinder.
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TRSMVD-0090LFC -RM STELFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0120LFB -RM STELFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0150LFB -RM STELFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0180LFB -RM STELFLOW 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0210LFC -RM STELFLOW 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0250LFC -RM STELFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0300LFC -RM STELFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0350LFC -RM STELFLOW 350 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0400LFC -RM STELFLOW 400 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0450LFC -RM STELFLOW 450 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVD-0500LFC -RM STELFLOW 500 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0090LFC -RM STELFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0120LFB -RM STELFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0150LFB -RM STELFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0180LFB -RM STELFLOW 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0210LFC -RM STELFLOW 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0250LFC -RM STELFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0300LFC -RM STELFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0350LFC -RM STELFLOW 350 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0400LFC -RM STELFLOW 400 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0450LFC -RM STELFLOW 450 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRSMVI-0500LFC -RM STELFLOW 500 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TRSMVE-0150LFB -RM STELFLOW 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0180LFB -RM STELFLOW 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0210LFC -RM STELFLOW 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0250LFC -RM STELFLOW 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0300LFC -RM STELFLOW 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0350LFC -RM STELFLOW 350 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0400LFC -RM STELFLOW 400 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0450LFC -RM STELFLOW 450 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVE-0500LFC -RM STELFLOW 500 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0150LFB -RM STELFLOW 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0150LFB -RM STELFLOW 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0210LFC -RM STELFLOW 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0250LFC -RM STELFLOW 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0300LFC -RMSTELFLOW 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0350LFC -RM STELFLOW 350 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0400LFC -RM STELFLOW 400 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0450LFC -RM STELFLOW 450 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRSMVS-0500LFC -RM STELFLOW 500 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER
Manufacturer:
RM Cylinders
Company Name
RM Cylinders
Address
4 Valencia Park, Gilcar Way, Wakefield Europort
Postcode
WF10 5QS
Country
West Yorkshire

View All Listings by this Company

Print This Approval


#1909103

THERMAQ PROLITE range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909103
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre,
Marking:
PROLITE SS ON CYLINDER THERMAQ PROLITE, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TTPMVD-0090LFC THERMAQ PROLITE SS 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0120LFB THERMAQ PROLITE SS 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0150LFB THERMAQ PROLITE SS 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0180LFB THERMAQ PROLITE SS 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0210LFC THERMAQ PROLITE SS 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0250LFC THERMAQ PROLITE SS 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVD-0300LFC THERMAQ PROLITE SS 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0090LFC THERMAQ PROLITE SS 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0120LFB THERMAQ PROLITE SS 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0150LFB THERMAQ PROLITE SS 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0180LFB THERMAQ PROLITE SS 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0210LFC THERMAQ PROLITE SS 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0250LFC THERMAQ PROLITE SS 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTPMVI-0300LFC THERMAQ PROLITE SS 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
Thermaq Ltd
Company Name
Thermaq Ltd
Address
Sandbeds Trading Estate Dewsbury Road Ossett
Postcode
WF5 9ND
Country
West Yorkshire
General Email
steve.woollas@rmcylinders.com

View All Listings by this Company

Print This Approval


#1909104

THERMAQ EVOCYL range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909104
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre, 350 litre, 400 litre, 450 litre, 500 litre.
Marking:
THERMAQ EVOCYL ON CYLINDER THERMAQ EVOCYL, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TTEMVD-0090LFC -THERMAQ EVOCYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0120LFB -THERMAQ EVOCYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0150LFB -THERMAQ EVOCYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER TTEMVD-0180LFB -THERMAQ EVOCYL 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0210LFC -THERMAQ EVOCYL 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0250LFC -THERMAQ EVOCYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0300LFC -THERMAQ EVOCYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0350LFC -THERMAQ EVOCYL 350 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0400LFC -THERMAQ EVOCYL 400 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0450LFC -THERMAQ EVOCYL 450 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVD-0500LFC -THERMAQ EVOCYL 500 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0090LFC -THERMAQ EVOCYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0120LFB -THERMAQ EVOCYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0150LFB -THERMAQ EVOCYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0180LFB -THERMAQ EVOCYL 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0210LFC -THERMAQ EVOCYL 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0250LFC -THERMAQ EVOCYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0300LFC -THERMAQ EVOCYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0350LFC -THERMAQ EVOCYL 350 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0400LFC -THERMAQ EVOCYL 400 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0450LFC -THERMAQ EVOCYL 450 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTEMVI-0500LFC -THERMAQ EVOCYL 500 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TTEMVE-0150LFB -THERMAQ EVOCYL 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0180LFB -THERMAQ EVOCYL 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0210LFC -THERMAQ EVOCYL 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0250LFC -THERMAQ EVOCYL 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0300LFC -THERMAQ EVOCYL 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0350LFC -THERMAQ EVOCYL 350 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0400LFC -THERMAQ EVOCYL 400 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0450LFC -THERMAQ EVOCYL 450 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVE-0500LFC -THERMAQ EVOCYL 500 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0150LFB -THERMAQ EVOCYL 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0180LFB -THERMAQ EVOCYL 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0210LFC -THERMAQ EVOCYL 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0250LFC -THERMAQ EVOCYL 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0300LFC -THERMAQ EVOCYL 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0350LFC -THERMAQ EVOCYL 350 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0400LFC -THERMAQ EVOCYL 400 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0450LFC -THERMAQ EVOCYL 450 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTEMVS-0500LFC -THERMAQ EVOCYL 500 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER
Factor:
Thermaq Ltd
Company Name
Thermaq Ltd
Address
Sandbeds Trading Estate Dewsbury Road Ossett
Postcode
WF5 9ND
Country
West Yorkshire
General Email
steve.woollas@rmcylinders.com

View All Listings by this Company

Print This Approval


#1909105

THERMAQ UNICYL range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909105
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre,
Marking:
THERMAQ UNICYL ON CYLINDER THERMAQ UNICYL, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TTUMVD-0090LFC -THERMAQ UNICYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0120LFB -THERMAQ UNICYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0150LFB -THERMAQ UNICYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0180LFB -THERMAQ UNICYL 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0210LFC -THERMAQ UNICYL 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0250LFC -THERMAQ UNICYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVD-0300LFC -THERMAQ UNICYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0090LFC -THERMAQ UNICYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0120LFB -THERMAQ UNICYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0150LFB -THERMAQ UNICYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0180LFB -THERMAQ UNICYL 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0210LFC -THERMAQ UNICYL 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0250LFC -THERMAQ UNICYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVI-0300LFC -THERMAQ UNICYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0150LFB -THERMAQ UNICYL 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0180LFB -THERMAQ UNICYL 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0210LFC -THERMAQ UNICYL 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0250LFC -THERMAQ UNICYL 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVE-0300LFC -THERMAQ UNICYL 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0150LFB -THERMAQ UNICYL 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0180LFB -THERMAQ UNICYL 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0210LFC -THERMAQ UNICYL 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0250LFC -THERMAQ UNICYL 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TTUMVS-0300LFC -THERMAQ UNICYL 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
Thermaq Ltd
Company Name
Thermaq Ltd
Address
Sandbeds Trading Estate Dewsbury Road Ossett
Postcode
WF5 9ND
Country
West Yorkshire
General Email
steve.woollas@rmcylinders.com

View All Listings by this Company

Print This Approval


#1909106

JOULE CYCLONE range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909106
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre, 350 litre, 400 litre, 450 litre, 500 litre.
Marking:
JOULE ON CYLINDER, JOULE CYCLONE, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TCEMVD-0090LFD -JOULE CYCLONE 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0120LFD-JOULE CYCLONE 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0150LFD -JOULE CYCLONE 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0180LFD -JOULE CYCLONE 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0210LFC -JOULE CYCLONE 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVD-0250LFC -JOULE CYCLONE 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0300LFC -JOULE CYCLONE 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0350LFC -JOULE CYCLONE 350 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0400LFC -JOULE CYCLONE 400 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0450LFC -JOULE CYCLONE 450 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVD-0500LFC -JOULE CYCLONE 500 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0090LFB -JOULE CYCLONE 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0120LFB -JOULE CYCLONE 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0150LFB -JOULE CYCLONE 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVI-0180LFB -JOULE CYCLONE 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0210LFC -JOULE CYCLONE 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0250LFC -JOULE CYCLONE 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0300LFD-JOULE CYCLONE 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0350LFC -JOULE CYCLONE 350 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVI-0400LFC -JOULE CYCLONE 400 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0450LFC -JOULE CYCLONE 450 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TCEMVI-0500LFC -JOULE CYCLONE 500 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER TCEMVE-0150LFB -JOULE CYCLONE 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0180LFB -JOULE CYCLONE 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0210LFC -JOULE CYCLONE 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0250LFC -JOULE CYCLONE 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0300LFC -JOULE CYCLONE 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0350LFC -JOULE CYCLONE 350 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0400LFC -JOULE CYCLONE 400 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TCEMVE-0450LFC -JOULE CYCLONE 450 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVE-0500LFC -JOULE CYCLONE 500 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0150LFB -JOULE CYCLONE 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0180LFB -JOULE CYCLONE 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0210LFC -JOULE CYCLONE 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TECMVS-0250LFC -JOULE CYCLONE 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TECMVS-0300LFC -JOULE CYCLONE 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0350LFC -JOULE CYCLONE350 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER TCEMVS-0400LFC -JOULE CYCLONE 400 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0450LFC -JOULE CYCLONE 450 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TCEMVS-0500LFC -JOULE CYCLONE 500 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER
Factor:
JOULE HOT WATER SYSTEMS
Company Name
JOULE HOT WATER SYSTEMS
Address
4 VALENCIA PARK GILCAR WAY WAKEFIELD EUROPORT
Postcode
WF10 5QS
Country
WEST YORKSHIRE

View All Listings by this Company

Print This Approval


#1909107

ZIP AQUAFLO II range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909107
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre,
Marking:
ZIP AQUAFLO II ON CYLINDER BODY ZIP AQUAFLO II, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
AF3090-ZIP AQUFLO II 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3120 -ZIP AQUAFLO II 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER AF3150 -ZIP AQUAFLO II 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3180 -ZIP AQUAFLO II 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3210 -ZIP AQUAFLO II 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3250 -ZIP AQUAFLO II 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3300 -ZIP AQUAFLO II 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4090 – ZIP AQUAFLO II 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4120 – ZIP AQUAFLO II 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4150 - ZIP AQUAFLO II 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4180 - ZIP AQUAFLO II 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4210 - ZIP AQUAFLO II 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4250 - ZIP AQUAFLO II 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4300 - ZIP AQUAFLO II 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF6150 - ZIP AQUAFLO II 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6180 - ZIP AQUAFLO II 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER AF6210 - ZIP AQUAFLO II 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6250 - ZIP AQUAFLO II 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6300 - ZIP AQUAFLO II 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF5150 - ZIP AQUAFLO II 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5180 - ZIP AQUAFLO II 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5210 - ZIP AQUAFLO II 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5250 - ZIP AQUAFLO II 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5300 - ZIP AQUAFLO II 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
Zip Heaters (UK) Ltd.
Company Name
Zip Heaters (UK) Ltd.
Address
14/15 Bertie Ward Way Rash's Green Dereham
Postcode
NR19 1TE
Country
Norfolk
Phone
01632 853 181
General Email
sales@zipheaters.co.uk

View All Listings by this Company

Print This Approval


#1909108

PROSTEL range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909108
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre
Marking:
PROSTEL UNVENTED HEATER ON CYLINDER RM PROSTEL, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TRPMVD-0090LFC -RM PROSTEL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0120LFB -RM PROSTEL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0150LFB -RM PROSTEL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0180LFB -RM PROSTEL 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0210LFC -RM PROSTEL 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0250LFC -RM PROSTEL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0300LFC -RM PROSTEL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER TRPMVI-0090LFC -RM PROSTEL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0120LFB -RM PROSTEL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0150LFB -RM PROSTEL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0180LFB -RM PROSTEL 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0210LFC -RM PROSTEL 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0250LFC -RM PROSTEL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0300LFC -RM PROSTEL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0150LFB -RM PROSTEL 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0180LFB -RM PROSTEL 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TRPMVE-0210LFC -RM PROSTEL 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0250LFC -RM PROSTEL 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0300LFC -RM PROSTEL 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TRPMVS-0150LFB -RM PROSTEL 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0180LFB -RM PROSTEL 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0210LFC -RM PROSTEL 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0250LFC -RM PROSTEL 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0300LFC -RM PROSTEL 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
RM Cylinders
Company Name
RM Cylinders
Address
4 Valencia Park, Gilcar Way, Wakefield Europort
Postcode
WF10 5QS
Country
West Yorkshire

View All Listings by this Company

Print This Approval


#1911012

Range of “Excelsior” stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911012
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
Fabdec, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Product Range: External expansion ranges: Excelsior Direct:80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior indirect: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Solar Direct: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Solar Indirect: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Heat Pump (single coil): 150L, 175L, 215L, 255L, 305L,400L, 500L Excelsior Heat Pump (twin coil): 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Direct slim line: 100L, 130L, 150L, 175L, 210L Excelsior indirect slim line: 100L, 130L, 150L, 175L, 210L Excelsior Direct super slim line: 80L, 100L, 130L, 150L, 165L Excelsior indirect super slim line: 80L, 100L, 130L, 150L, 165L Excelsior Renewables’, slim line: 100L. 130L, 150L, 175L, 210L Excelsior Buffer: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L
Factor:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company

Print This Approval


#1911034

Range of MAXXflo EVO free standing gas fired stainless steel unvented storage cylinders. The heaters are supplied with temperature and pressure relief valves (rated 10.0 bar @ 95°C), pressure reducing valve (rated 6.0 bar) & expansion relief valve (rated 8.0 bar). The manifold incorporates a stainless-steel strainer, flexible hose, expansion vessel and approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7.5 bar. Cold water supply only.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911034
Expiry date:
30/11/2024
Size:
1½” BSP (M)
Marking:
Andrews Water Heaters & technical information on adhesive label.
Installation Requirements:
R001 R530 R140 R360
Model:
CWH 30/201 (30kW heat input with 200 litre tank) CWH 30/301 (30kW heat input with 300 litre tank) CWH 60/201 (60kW heat input with 200 litre tank) CWH 60/301 (60kW heat input with 300 litre tank) CWH 90/302 (90kW heat input with 300 litre tank) CWH 120/302 (120kW heat input with 300 litre tank)
Factor:
Andrews Water Heaters
Company Name
Andrews Water Heaters
Address
Baxi Commercial Division Wood Lane Erdington
Postcode
B24 9QP
Country
Birmingham
Phone
0845 070 1056
General Email
andrews@andrews-waterheaters.co.uk

View All Listings by this Company

Print This Approval


#1911059

Range of “Mixergy” stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911059
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
MIXERGY, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
MIXERGY DIRECT CYLINDER 90L, 130L, 150L, 175L & 215L MIXERGY INDIRECT CYLINDER 130L, 150L, 175L, 215L & 305L
Factor:
Mixergy Ltd.
Company Name
Mixergy Ltd.
Address
2 Canal View Wharf Farm Eynsham
Postcode
OX29 4DB
Country
Oxfordshire

View All Listings by this Company

Print This Approval


#1911060

BTMB Range of stainless steel indirect unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911060
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
SAHP, Model number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
BTMB 130 BTMB 200 & BTMB 300
Factor:
SAHP LIMITED
Company Name
SAHP LIMITED
Address
UNIT 2 GALIFORD ROAD MALDON ESSE
Postcode
CM9 4XD

View All Listings by this Company

Print This Approval


#2006003

Range of indirectly heated stainless-steel storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar is provided. A tundish, expansion vessel and an approved filling loop is also supplied Maximum working pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 2.5 bar. Maximum operating temperature 70˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2006003
Expiry date:
30/06/2025
Marking:
Mitsubishi and Ecodan on front of unit. Mitsubishi, model and technical info including pressures and capacity on adhesive label on top of unit.
Installation Requirements:
R001 R140 R530 R360
Model:
EHPT20X-MHCW. EHST20C-MHCW. EHST20D-MHCW.
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2007040

Fabdec ‘Excelsior’ ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2007040
Expiry date:
31/07/2025
Note:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°C.
Size:
See model
Marking:
Adhesive label on side of cylinder with manufacturers name (Fabdec), model, address and technical information including temperature, capacity and pressure.
Installation Requirements:
R001 R140 R360
Model:
Internal expansion ranges. Excelsior Direct, Indirect, Solar Direct & Solar Indirect Cylinders range: 80ltr, 130ltr, 150ltr, 175ltr, 215ltr, 255ltr, 300ltr, 400ltr, 500ltr.
Manufacturer:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company

Print This Approval


#1911070

Range of Stuart Aquastor Eco stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911070
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
STUART TURNER, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Indirect- Stuart Aquastor Eco: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L SAE 130 SAE 150 SAE 215 SAE 255 SAS 305 SAS400 SAS 500
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2011335

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2011335
Expiry date:
30/11/2025
Size:
22mm compression
Marking:
Gledhill and product & technical information on adhesive label on body
Installation Requirements:
R001 R140 R360
Model:
Directs range PLTDR120 Platinum Int Exp Dir 120 PLTDR150 Platinum Int Exp Dir 150 PLTDR180 Platinum Int Exp Dir 180 PLTDR210 Platinum Int Exp Dir 210 PLTDR250 Platinum Int Exp Dir 250 PLTDR300 Platinum Int Exp Dir 300 Indirect range PLTIN120 Platinum Int Exp Ind 120 PLTIN150 Platinum Int Exp Ind 150 PLTIN180 Platinum Int Exp Ind 180 PLTIN210 Platinum Int Exp Ind 210 PLTIN250 Platinum Int Exp Ind 250 PLTIN300 Platinum Int Exp Ind 300 Pre-Plumbed Range PLTIN120PP Platinum Int Exp Ind 120 PP PLTIN150PP Platinum Int Exp Ind 150 PP PLTIN180PP Platinum Int Exp Ind 180 PP PLTIN210PP Platinum Int Exp Ind 210 PP PLTIN250PP Platinum Int Exp Ind 250 PP PLTIN300PP Platinum Int Exp Ind 300 PP System Plus Range PLTIN120PPSP Platinum Int Exp Ind 120 PPSP PLTIN150PPSP Platinum Int Exp Ind 150 PPSP PLTIN180PPSP Platinum Int Exp Ind 180 PPSP PLTIN210PPSP Platinum Int Exp Ind 210 PPSP PLTIN250PPSP Platinum Int Exp Ind 250 PPSP PLTIN300PPSP Platinum Int Exp Ind 300 PPSP System Ready Range PLTIN120PPSR Platinum Int Exp Ind 120 PPSR PLTIN150PPSR Platinum Int Exp Ind 150 PPSR PLTIN180PPSR Platinum Int Exp Ind 180 PPSR PLTIN210PPSR Platinum Int Exp Ind 210 PPSR PLTIN250PPSR Platinum Int Exp Ind 250 PPSR PLTIN300PPSR Platinum Int Exp Ind 300 PPSR
Manufacturer:
Gledhill Building Products Ltd
Company Name
Gledhill Building Products Ltd
Address
Sycamore Estate Blackpool
Postcode
FY4 3RL
Phone
(01253) 474439

View All Listings by this Company

Print This Approval


#1911074

Range of Advance Appliance stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911074
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
ADVANCE APPLIANCES, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Advance Appliances- Heat Pump- single coil HP 135/ 150/215/ 255/ 305 HPL 255/ 305/ 400/ 500 Advance Appliances- Heat Pump - twin coil HPS 215/ 255/ 305 HPSL 305/ 400/ 500 Advance Appliances- Buffer Store - BFS 80/ 150/ 215/ 255/ 305/ 500
Factor:
Advance Appliances Ltd.
Company Name
Advance Appliances Ltd.
Address
Unit 4 Coppice Side Industrial Estate, Brownhills, Walsall
Postcode
WS8 7EX

View All Listings by this Company

Print This Approval


#2007084

Advance Appliance ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2007084
Expiry date:
31/07/2025
Note:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°C.
Size:
See model
Marking:
Adhesive label on side of cylinder with Advance Appliances model, address and technical information including temperature, capacity and pressure.
Installation Requirements:
R001 R140 R360
Model:
Advances Appliances Indirect - single coil ipp 175 Advance Appliances Indirect- single coil ipp 250
Factor:
Advance Appliances Ltd.
Company Name
Advance Appliances Ltd.
Address
Unit 4 Coppice Side Industrial Estate, Brownhills, Walsall
Postcode
WS8 7EX

View All Listings by this Company

Print This Approval


#1911075

Range of Element stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911075
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
Element by Dutypoint on front of body Dutypoint, WRAS, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Product Range: External expansion ranges: Element Direct:80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element indirect: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Solar Direct: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Solar Indirect: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Heat Pump (single coil): 150L, 175L, 215L, 255L, 305L,400L, 500L Element Heat Pump (twin coil): 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Direct slim line: 100L, 130L, 150L, 175L, 210L Element indirect slim line: 100L, 130L, 150L, 175L, 210L Element Direct super slim line: 80L, 100L, 130L, 150L, 165L Element indirect super slim line: 80L, 100L, 130L, 150L, 165L Element Renewables’, slim line: 100L. 130L, 150L, 175L, 210L Element Buffer: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L
Factor:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2103025

Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103025
Expiry date:
31/03/2026
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Telford solar on label. Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Model:
TSMIXXX - Tempest indirect XXXL single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMIXXX/S - Tempest indirect XXXL twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMDXXX - Tempest direct XXXL electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L.
Manufacturer:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval


#2103009

Whitewolf Alpha ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103009
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
Whitewolf Cylinders on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
WWA90D - Whitewolf Alpha 90 Direct WWA120D - Whitewolf Alpha 120 Direct WWA150D - Whitewolf Alpha 150 Direct WWA170D - Whitewolf Alpha 170 Direct WWA200D - Whitewolf Alpha 200 Direct WWA250D - Whitewolf Alpha 250 Direct WWA300D - Whitewolf Alpha 300 Direct WWA90I - Whitewolf Alpha 90 Indirect WWA120I - Whitewolf Alpha 120 Indirect WWA150I - Whitewolf Alpha 150 Indirect WWA170I - Whitewolf Alpha 170 Indirect WWA200I - Whitewolf Alpha 200 Indirect WWA250I - Whitewolf Alpha 250 Indirect WWA300I - Whitewolf Alpha 300 Indirect WWA170S - Whitewolf Alpha 170 Indirect Solar Single Coil WWA200S - Whitewolf Alpha 200 Indirect Solar Single Coil WWA250S - Whitewolf Alpha 250 Indirect Solar Single Coil WWA300S - Whitewolf Alpha 300 Indirect Solar Single Coil WWA170T - Whitewolf Alpha 170 Indirect Solar Twin Coil WWA200T - Whitewolf Alpha 200 Indirect Solar Twin Coil WWA250T - Whitewolf Alpha 250 Indirect Solar Twin Coil WWA300T - Whitewolf Alpha 300 Indirect Solar Twin Coil WWAS60D - Whitewolf Alpha Slim 60 Direct WWAS90D - Whitewolf Alpha Slim 90 Direct WWAS120D - Whitewolf Alpha Slim 120 Direct WWAS150D - Whitewolf Alpha Slim 150 Direct WWAS170D - Whitewolf Alpha Slim 170 Direct WWAS200D - Whitewolf Alpha Slim 200 Direct WWAS60I - Whitewolf Alpha Slim 60 Indirect WWAS90I - Whitewolf Alpha Slim 90 Indirect WWAS120I - Whitewolf Alpha Slim 120 Indirect WWAS150I - Whitewolf Alpha Slim 150 Indirect WWAS170I - Whitewolf Alpha Slim 170 Indirect WWAS200I - Whitewolf Alpha Slim 200 Indirect
Factor:
Whitewolf Cylinders Ltd
Company Name
Whitewolf Cylinders Ltd
Address
Unit 2, 30 Junction Business Park 119/121 Ouzlewell Green Lofthouse, West Yorkshire
Postcode
WF3 3QW
Country
United Kingdom
Phone
01132 822710
General Email
mail@whitewolfcylinders.com

View All Listings by this Company

Print This Approval


#2103028

Elite ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103028
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
UK CYLINDERS ELITE on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
ESDIR0090 – UK CYLINDERS ELITE 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0120 – UK CYLINDERS ELITE 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0150 – UK CYLINDERS ELITE 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0170 – UK CYLINDERS ELITE 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0200 – UK CYLINDERS ELITE 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0250 – UK CYLINDERS ELITE 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0300 – UK CYLINDERS ELITE 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. ESIND0090-UK CYLINDERS ELITE 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0120-UK CYLINDERS ELITE 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0150-UK CYLINDERS ELITE 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. ESIND0170-UK CYLINDERS ELITE 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0200-UK CYLINDERS ELITE 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0250-UK CYLINDERS ELITE 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. ESIND0300-UK CYLINDERS ELITE 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESSDI0170-UK CYLINDERS ELITE 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSDI0200-UK CYLINDERS ELITE 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSDI0250-UK CYLINDERS ELITE 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSDI0300-UK CYLINDERS ELITE 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSIN0170-UK CYLINDERS ELITE 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER ESSIN0200-UK CYLINDERS ELITE 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. ESSIN0250-UK CYLINDERS ELITE 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER ESSIN0300-UK CYLINDERS ELITE 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. ESNDI0060-UK CYLINDERS ELITE SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0090-UK CYLINDERS ELITE SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0120-UK CYLINDERS ELITE SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0150-UK CYLINDERS ELITE SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0170-UK CYLINDERS ELITE SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0200-UK CYLINDERS ELITE SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0060-UK CYLINDERS ELITE SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0090-UK CYLINDERS ELITE SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0120-UK CYLINDERS ELITE SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0150-UK CYLINDERS ELITE SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0170-UK CYLINDERS ELITE SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0200-UK CYLINDERS ELITE SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
UK CYLINDERS LTD
Company Name
UK CYLINDERS LTD
Address
UNIT 3 RCM BUSINESS CENTRE WEST YORKSHIRE
Postcode
WF5 9ND

View All Listings by this Company

Print This Approval


#2103029

Flowcyl ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103029
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
UK CYLINDERS FLOWCYL on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
FCDIR0090-UK CYLINDERS FLOWCYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0120 – UK CYLINDERS FLOWCYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0150 – UK CYLINDERS FLOWCYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0170 – UK CYLINDERS FLOWCYL 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0200 – UK CYLINDERS FLOWCYL 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0250 – UK CYLINDERS FLOWCYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0300 – UK CYLINDERS FLOWCYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. FCIND0090-UK CYLINDERS FLOWCYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0120-UK CYLINDERS FLOWCYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0150-UK CYLINDERS FLOWCYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. FCIND0170-UK CYLINDERS FLOWCYL 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0200-UK CYLINDERS FLOWCYL 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0250-UK CYLINDERS FLOWCYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. FCIND0300-UK CYLINDERS FLOWCYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCSDI0170-UK CYLINDERS FLOWCYL 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSDI0200-UK CYLINDERS FLOWCYL 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSDI0250-UK CYLINDERS FLOWCYL 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSDI0300-UK CYLINDERS FLOWCYL 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSIN0170-UK CYLINDERS FLOWCYL 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER FCSIN0200-UK CYLINDERS FLOWCYL 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. FCSIN0250-UK CYLINDERS FLOWCYL 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER FCSIN0300-UK CYLINDERS FLOWCYL 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. FCNDI0060-UK CYLINDERS FLOWCYL SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0090-UK CYLINDERS FLOWCYL SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0120-UK CYLINDERS FLOWCYL SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0150-UK CYLINDERS FLOWCYL SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0170-UK CYLINDERS FLOWCYL SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0200-UK CYLINDERS FLOWCYL SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0060-UK CYLINDERS FLOWCYL SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0090-UK CYLINDERS FLOWCYL SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0120-UK CYLINDERS FLOWCYL SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0150-UK CYLINDERS FLOWCYL SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0170-UK CYLINDERS FLOWCYL SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0200-UK CYLINDERS FLOWCYL SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
UK CYLINDERS LTD
Company Name
UK CYLINDERS LTD
Address
UNIT 3 RCM BUSINESS CENTRE WEST YORKSHIRE
Postcode
WF5 9ND

View All Listings by this Company

Print This Approval


#2103031

Nucyl ranges of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103031
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
UK CYLINDERS NUCYL on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
WWA90D -WHITEWOLF ALPHA 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0090-UK CYLINDERS NUCYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA120D -WHITEWOLF ALPHA 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0120 – UK CYLINDERS NUCYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA150D -WHITEWOLF ALPHA 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0150 – UK CYLINDERS NUCYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA170D -WHITEWOLF ALPHA 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0170 – UK CYLINDERS NUCYL 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA200D -WHITEWOLF ALPHA 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0200 – UK CYLINDERS NUCYL 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA250D -WHITEWOLF ALPHA 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FNUIR0250 – UK CYLINDERS NUCYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA300D -WHITEWOLF ALPHA 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. NUDIR0300 – UK CYLINDERS NUCYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. WWA90I -WHITEWOLF ALPHA 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0090-UK CYLINDERS NUCYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA120I -WHITEWOLF ALPHA 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0120-UK CYLINDERS NUCYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA150I-WHITEWOLF ALPHA 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. NUIND0150-UK CYLINDERS NUCYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. WWA170I-WHITEWOLF ALPHA 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0170-UK CYLINDERS NUCYL 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA200IWHITEWOLF ALPHA 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0200-UK CYLINDERS NUCYL 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA250I-WHITEWOLF ALPHA 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. NUIND0250-UK CYLINDERS NUCYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. WWA300I-WHITEWOLF ALPHA 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0300-UK CYLINDERS NUCYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
UK CYLINDERS LTD
Company Name
UK CYLINDERS LTD
Address
UNIT 3 RCM BUSINESS CENTRE WEST YORKSHIRE
Postcode
WF5 9ND

View All Listings by this Company

Print This Approval


#2104314

Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104314
Expiry date:
30/04/2026
Size:
1” BSP(M) x 1”BSP(M)
Marking:
Therm’inova, serial no, gas type, capacity and other techcnial information on body.
Installation Requirements:
R001 R140
Model:
COE / NHREC 18 kW (G20/G25/G31) COE / NHREC 36 kW (G20/G25/G31) COE / NHREC 60 kW (G20/G25/G31) AEALN / NHREX 18 kW (G20/G25/G31) AEALN / NHREX 26 kW (G20/G25/G31) AEALN / NHREX 36 kW (G20/G25/G31) AEALN / NHREX 60 kW (G20/G25/G31) The AEALN / NHREX family of product has straight exhaust that goes from the burner through the tank up to the top of the water heater The COE family of product has a corkscrew exhaust that goes through the tank and exit at the base of the water heater Each water heater through specific setting can be used with 3 different type of gas: - G 20 = Methane - G 25 = Town Gas - G31 = Propane (LPG)
Manufacturer:
Therm'inova
Company Name
Therm'inova
Address
1 Rue Des Bornes 27140 Gisors
Country
France
Phone
+33 (0)2 32 27 85 08

View All Listings by this Company

Print This Approval


#2103330

Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump? Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103330
Expiry date:
31/03/2026
Size:
1 ¼” BSP(F) x 1 ¼” BSP(F)
Marking:
Polar Energi, model no, date of manufacture, capacity,& pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
VP380L
Factor:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222
General Email
post@polarenergi.com

View All Listings by this Company

Print This Approval


#2106034

Range of “POWERflow” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 4.5 bar at 90˚C and an expansion relief valve set at 3.5 bar. The product is supplied with a pressure reducing valve set at 2.1 bar, expansion vessel, tundish and an approved check assembly (suitable for backflow protection against Fluid Category 2). Primary circuit max working pressure: 3.5 bar Secondary circuit max working pressure: 3.0 bar Solar Coil max working pressure: 3.5 bar Primary and Secondary circuit maximum operating temperature 75.0°C Solar Coil max operating temperature 80.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2106034
Expiry date:
30/06/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
Primary Circuit: 22mm compression. Secondary circuit: 22mm compression. Solar circuit: 22mm compression. Drain connection: 15mm compression.
Marking:
McDonald Water Storage, POWERflow and other product info on labels on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
POWERflow Range of unvented hot water storage cylinders: 75, 120, 150, 165, 180, 210, 250, 300 Litres Indirect & Direct. Solar Coil option on 120L and above. PD1 - 75 Litre Direct POWERflow, PI1 - 75 Litre Indirect POWERflow Size = 950 x 450mm Connections = 6 (Direct) / 9 (Indirect) PD2 - 120 Litre Direct POWERflow, PI2 - 120 Litre Indirect POWERflow Size = 950 x 550mm Connections = 6 (Direct) / 9 (Indirect) PD3 - 150 Litre Direct POWERflow, PI3 - 150 Litre Indirect POWERflow Size = 1150 x 550mm Connections = 7 (Direct) / 9 (Indirect) PD5 - 165 Litre Direct POWERflow, PI5 - 165 Litre Indirect POWERflow Size = 1250 x 550mm Connections = 7 (Direct) / 9 (Indirect) PD6 - 180 Litre Direct POWERflow, PI6 - 180 Litre Indirect POWERflow Size = 1350 x 550mm Connections = 8 (Direct) / 10 (Indirect) PD4 - 210 Litre Direct POWERflow, PI4 - 210 Litre Indirect POWERflow Size = 1550 x 550mm Connections = 8 (Direct) / 10 (Indirect) PD7 - 250 Litre Direct POWERflow, PI7 - 250 Litre Indirect POWERflow Size = 1550 x 600mm Connections = 8 (Direct) / 10 (Indirect) PD8 - 300 Litre Direct POWERflow, PI8 - 300 Litre Indirect POWERflow Size = 1850 x 600mm Connections = 8 (Direct) / 10 (Indirect)
Manufacturer:
MCDONALD WATER STORAGE
Company Name
MCDONALD WATER STORAGE
Address
QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE
Postcode
KY7 5QF

View All Listings by this Company

Print This Approval


#2107032

Mitsubishi Electric ‘EHPT20Q – VM2EA’ stainless steel unvented primary thermal store cylinder unit. An inline booster heater is also fitted into the primary circuit. The cylinder is fitted with two pressure relief valves set at 3.0 bar. Heat is transferred from the stored primary water to the secondary water circuit via a plate heat exchanger which provides instantaneous hot water. The primary thermal storage cylinder is to be filled by the use of the supplied temporary filling loop assembly, which consistd of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly (suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve. A primary expansion vessel is supplied to accommodate the expansion of the primary water when heated. An automatic air vent is fitted to the top of the thermal store. The product is supplied with a tundish. Maximum working pressure: Primary circuit 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature: Primary circuit 72°C, Secondary circuit 70°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2107032
Expiry date:
31/07/2026
Size:
Primary and Secondary circuit: 22mm connection. Outdoor heating unit: ½” BSP (M)
Marking:
Mitsubishi, model and technical information including capacity and pressure on adhesive label on top of unit.
Installation Requirements:
R001
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
EHPT20Q-VM2EA
Factor:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2103035

McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103035
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
McDonald Water Storage & Steel Flow on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
CS90D - MCDONALD STEELFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120D - MCDONALD STEELFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150D - MCDONALD STEELFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170D - MCDONALD STEELFLOW 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200D - MCDONALD STEELFLOW 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS250D - MCDONALD STEELFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS300D - MCDONALD STEELFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS90I - MCDONALD STEELFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120I - MCDONALD STEELFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150I - MCDONALD STEELFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS170I - MCDONALD STEELFLOW 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200I - MCDONALD STEELFLOW 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS250I - MCDONALD STEELFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS300I - MCDONALD STEELFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170DS - MCDONALD STEELFLOW 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS200DS - MCDONALD STEELFLOW 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS250DS - MCDONALD STEELFLOW 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS300DS - MCDONALD STEELFLOW 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS170IS - MCDONALD STEELFLOW 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER CS200IS - MCDONALD STEELFLOW 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. CS325IS - MCDONALD STEELFLOW 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER CS300IS - 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. CS60DSL - MCDONALD STEELFLOW SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS90DSL - MCDONALD STEELFLOW SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120DSL - MCDONALD STEELFLOW SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150DSL - MCDONALD STEELFLOW SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170DSL - MCDONALD STEELFLOW SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200DSL - MCDONALD STEELFLOW SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS60ISL - MCDONALD STEELFLOW SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS90ISL - MCDONALD STEELFLOW SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120ISL - MCDONALD STEELFLOW SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150ISL - MCDONALD STEELFLOW SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170ISL - MCDONALD STEELFLOW SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200ISL - MCDONALD STEELFLOW SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
MCDONALD WATER STORAGE
Company Name
MCDONALD WATER STORAGE
Address
QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE
Postcode
KY7 5QF

View All Listings by this Company

Print This Approval


#2103340

Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103340
Expiry date:
31/03/2026
Size:
1 ¼” BSP(F) x 1 ¼” BSP(F)
Marking:
Polar Energi, model no, date of manufacture, capacity,& pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
PAW-VP380L INDIRECT THERMAL STORE
Factor:
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Company Name
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Address
Maxis 2 Western Road Bracknell Berkshire
Postcode
RG12 1RT

View All Listings by this Company
Manufacturer:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222

View All Listings by this Company

Print This Approval


#2107329

SSB, SSI SST range of stainless steel unvented cylinders provided with an unvented kit supplied with cylinders containing a temperature and pressure reducing valve set at 3.0 bar and an expansion vessel and single check valve (suitable for fluid category 2) . Available as storage tank, indirect or twin coil. Maximum working pressure of the cylinder 6.0 bar, maximum working pressure of the coil or coils 12.0 bar. Maximum operating temperature 95°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2107329
Expiry date:
31/07/2026
Size:
See model
Marking:
Adveco on body. Adveco logo, model no, pressure, temp and other technical information on data label on body.
Installation Requirements:
R001 R140
Model:
Model Capacity (L) SSB200 191 SSB300 286 SSB500 481 SSB800 763 SSB1000 952 SSB1500 1426 SSB2000 2002 SSB2500 2535 No coils 1 x blanking plate in upper flange 1x blanking plate in lower flange SSI200/1.0 188 SSI300/1.0 283 SSI500/1.5 476 SSI800/1.5 758 SSI800/3.0 753 SSI1000/5.0 935 SSI1500/4.0 1413 SSI1500/6.0 1407 SSI 2000/4.0 1989 SSI 2000/6.0 1983 SSI 2500/4.0 2522 SSI 2500/6.0 2516 1 x blanking plate in upper flange 1 x coil in lower flange
SST200/1.0 184 SST300/1.0 279 SST500/1.5 470 SST800/1.5 752 SST800/3.0 743 SST1000/5.0 918 SST1500/4.0 1399 SST1500/6.0 1387 SST2000/4.0 1975 SST2000/6.0 1963 SST2500/4.0 2508 SST2500/6.0 2496 1 x coil in upper flange 1 x coil in lower flange
Manufacturer:
Adveco Ltd
Company Name
Adveco Ltd
Address
Unit 7 & 8 Armstrong Mall Southwood Business Park Farnborough Hants
Postcode
GU14 0NR
Country
United Kingdom
Phone
01252 551 540

View All Listings by this Company

Print This Approval


#2104330

Range of domestic stainless steel indirect unvented hot water storage cylinder incorporating a stainless steel coil for connection to a heat pump circuit. The secondary circuit is factory fitted with a temperature and pressure relief valve (10 bar and 92°C) and an Incoloy immersion heater and magnesium sacrificial anode. Maximum working pressure: Secondary circuit 9.5 bar. Maximum operating temperature 95°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104330
Expiry date:
30/04/2026
Size:
1 ¼” BSP (F) x 1 ¼” BSP (F)
Marking:
Polar Energi, model number, date of manufacture (MM/YY), capacity & pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
VP200L DHW VP500L DHW VP750L DHW VP1000L DHW
Factor:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222
General Email
post@polarenergi.com

View All Listings by this Company

Print This Approval


#2110326

Range of indirect and direct unvented storage cylinders consisting of either no coil (GLE) or a factory fitted single (GLC) or twin coil (GLT). The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@85˚C for 1.0-6.0 bar products and 10.5 bar@95°C for 6.0-10.0 bar products. The products are supplied with an inlet control group (safety kit) consisting of a pressure reducing valve, an expansion relief valve 6.0 bar (1.0-6.0 bar products) or 10.5 bar (6.0-10.0 bar products) and an approved check valve, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is also supplied with an expansion vessel. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2110326
Expiry date:
31/10/2026
Size:
1 ½” BSP (M) secondary (inlet kit) 1 ½” BSF (F) secondary cylinder 1” BSP( F) primary coils
Marking:
Adveco badge on casing Serial No, Adveco, address, model no. capacity, & other tech info on adhesive label on body G3 warning label, maintenance label, service label, energy label on casing
Installation Requirements:
R001 R040
Model:
Adveco GLE Range GLE 200, GLE 300, GLE 500, GLE 750, GLE1000 Adveco GLC Range GLC 200, GLC 300, GLC 500, GLC 750, GLC 1000. Adveco GLT Range GLT 200, GLT 300, GLT 500, GLT 750, GLT1000
Factor:
Adveco Ltd
Company Name
Adveco Ltd
Address
Unit 7 & 8 Armstrong Mall Southwood Business Park Farnborough Hants
Postcode
GU14 0NR
Country
United Kingdom
Phone
01252 551 540
General Email
enquiries@adveco.co

View All Listings by this Company

Print This Approval


#2104346

Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104346
Expiry date:
30/04/2026
Size:
1” BSP(M) x 1”BSP(M)
Marking:
Elco, serial no, gas type, capacity and other techcnial on adhesive on label information on body.
Installation Requirements:
R001 R140
Model:
TUDOR NHREC 20 TUDOR NHREC 40 TUDOR NHREC 65 TUDOR NHREX 18 TUDOR NHREX 26 TUDOR NHREX 36 TUDOR NHREX 60 The AEALN / NHREX family of product has straight exhaust that goes from the burner through the tank up to the top of the water heater The COE family of product has a corkscrew exhaust that goes through the tank and exit at the base of the water heater Each water heater through specific setting can be used with 3 different type of gas: - G 20 = Methane - G 25 = Town Gas - G31 = Propane (LPG)
Factor:
Elco Heating Solutions Limited
Company Name
Elco Heating Solutions Limited
Address
Juniper West, 3 Fenton Way Southshields Business Park Basildon
Postcode
SS15 6SJ
Country
Essex
Phone
01268 546 700
General Email
enquiries@elco.co.uk

View All Listings by this Company

Print This Approval


#1911081

Infinty-E stainless steel direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911081
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
Rinnai, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
INFINITY-E HOT WATER STORAGE CYLINDER
Factor:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval


#2104347

Range of domestic stainless steel indirect unvented hot water storage cylinder incorporating a stainless steel coil for connection to a heat pump circuit. The secondary circuit is factory fitted with a temperature and pressure relief valve (10 bar and 92°C) and an Incoloy immersion heater and magnesium sacrificial anode. Maximum working pressure: Secondary circuit 9.5 bar. Maximum operating temperature 95°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104347
Expiry date:
30/04/2026
Size:
1 ¼” BSP (F) x 1 ¼” BSP (F)
Marking:
Polar Energi, model number, date of manufacture (MM/YY), capacity & pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
PAW-VP750L-DHW-1 & PAW-VP1000L-DHW-1 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Company Name
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Address
Maxis 2 Western Road Bracknell Berkshire
Postcode
RG12 1RT

View All Listings by this Company
Manufacturer:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222

View All Listings by this Company

Print This Approval


#2203041

Mitsubishi EHWT17D-MHEDW indirectly heated stainless-steel unvented storage cylinder consisting of plate heat exchangers. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of an approved single check valve cartridge (verified by test as suitable for backflow protection against Fluid Category 2), strainer, a pressure relief valve set at 6.0 bar and pressure reducing valve set at 3.5 bar. The space heating circuit is factory fitted with a pressure relief valve fitted rated at 3.0 bar and an automatic air vent. A tundish, expansion vessel and filling loop are also supplied. Maximum secondary (wholesome) circuit working pressure: 5.5 bar. Maximum Space heating (primary) circuit working pressure: 2.5 bar. Maximum brine/ambient circuit working pressure: 9.5 bar. Maximum operating temperature 70°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2203041
Expiry date:
31/03/2027
Size:
Secondary Circuit: 22mm compression. Space heating circuit: 28mm compression. Brine/Ambient circuit: 28mm compression.
Marking:
Company name and logo (Mitsubishi), max operating pressures, max operating temperature, capacity and other technical information on adhesive label on top of cylinder.
Installation Requirements:
R001 R140 R360
Model:
EHWT17D-MHEDW
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2204061

‘Comet’ combination units consisting of a cased and insulated stainless steel unvented hot water storage cylinder. The cylinder primary circuit is fitted with an in-line electrical heater which supplies the heat source to the secondary water via a stainless-steel coil, and the heat source to the central heating circuit directly. The cylinder is factory fitted with a temperature and pressure relief valve, pre-set at 7.0 bar 90 degrees. The unit is supplied with an inlet control group containing a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), pressure reducing valve set at 3.0 bar and an expansion relief set at 6.0 bar. An expansion vessel is factory fitted to both the secondary and primary circuits within and is positioned inside the casing. The primary circuit also incorporates a circulating pump and pressure relief valve which is set at 3.0 bar. Maximum secondary working pressure 5.5 Bar Maximum Primary working pressure 2.5 Bar Maximum operating temperature 65.0 °C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2204061
Expiry date:
30/04/2027
Size:
22 mm Compression
Marking:
Electric Heating company, max pressure, max temperature, capacity and other technical information on adhesive label on front door of the unit
Installation Requirements:
R001 R140 R360
Model:
EHCCOMCOMBI 9KW – 140 litres EHCCOMCCOMBI 12KW – 140 litres EHCOMCOMBI 14.4KW – 140 litres
Factor:
The Electric Heating Company
Company Name
The Electric Heating Company
Address
Unit 40 Block 5 Third Road Blantyre Ind Est
Postcode
G72 0UP
Country
Glasgow

View All Listings by this Company

Print This Approval


#2201019

Range of “MEGAAIR” bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2201019
Expiry date:
31/01/2027
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
“Whitewolf” and “Megaair” Logo on front of cylinder. Product data label consisting of capacity, pressures and other technical information on front of body.
Installation Requirements:
R001 R140 R360
Model:
WHITEWOLF MEGAAIR DIRECT UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 120 to 300 L): WWMxxxD WHITEWOLF MEGAAIR 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 120 to 300 L): WWMxxxI WHITEWOLF MEGAAIR 90 DIRECT SLIM UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 90 to 200 L): WWMSxxxD WHITEWOLF MEGAAIR 90 INDIRECT SLIM UNVENTED HOT WATER STORAGE CYLINDERS (Ranging from 90 to 200 L): WWMSxxxI Where xxx denotes the capacity in L and can be replaced by any of the following: 90, 120, 150, 170, 200, 250 or 300
Factor:
Whitewolf Cylinders Ltd
Company Name
Whitewolf Cylinders Ltd
Address
Unit 2, 30 Junction Business Park 119/121 Ouzlewell Green Lofthouse, West Yorkshire
Postcode
WF3 3QW
Country
United Kingdom
Phone
01132 822710
General Email
mail@whitewolfcylinders.com

View All Listings by this Company

Print This Approval


#2103036

Centerstore ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103036
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
Centerstore (Trademark of Wolseley) on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
174767 CENTERSTORE 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174768 CENTERSTORE 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174769 CENTERSTORE 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174770 CENTERSTORE 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174771 CENTERSTORE 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174772 CENTERSTORE 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDE 174773 CENTERSTORE 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174774 CENTERSTORE 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174787 CENTERSTORE SLIM 120 INDIRECT HOT WATER STORAGE CYLINDER 174788 CENTERSTORE SLIM 150 INDIRECT HOT WATER STORAGE CYLINDER 174789 CENTERSTORE SLIM 170 INDIRECT HOT WATER STORAGE CYLINDER 174790 CENTERSTORE SLIM 200 INDIRECT HOT WATER STORAGE CYLINDER 174791 CENTERSTORE SLIM 120 DIRECT HOT WATER STORAGE CYLINDER 174792 CENTERSTORE SLIM 150 DIRECT HOT WATER STORAGE CYLINDER 174793 CENTERSTORE SLIM 170 DIRECT HOT WATER STORAGE CYLINDER 174794 CENTERSTORE SLIM 200 DIRECT HOT WATER STORAGE CYLINDER
Factor:
Wolseley UK
Company Name
Wolseley UK
Address
K2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Phone
01926 705792

View All Listings by this Company

Print This Approval


#2201097

Range of CENTERSTORE AIR bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added March 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2201097
Expiry date:
31/01/2027
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
Centerstore (Trademark of Wolseley) on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Model:
174775- CENTERSTORE AIR 120 INDIRECT UNVENTED HOT WATER CYLINDER 174776- CENTERSTORE AIR 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174777- CENTERSTORE AIR 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174778- CENTERSTORE AIR 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174779- CENTERSTORE AIR 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174780-WOLSELEY CENTERSTORE AIR 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174781- CENTERSTORE AIR 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174782- CENTERSTORE AIR 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174783- CENTERSTORE AIR 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174784- CENTERSTORE AIR 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174785- CENTERSTORE AIR 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174786- CENTERSTORE AIR 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174795- CENTERSTORE AIR SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174796- CENTERSTORE AIR SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174797- CENTERSTORE AIR SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER 174798- CENTERSTORE AIR SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
Wolseley UK
Company Name
Wolseley UK
Address
K2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Phone
01926 705792

View All Listings by this Company

Print This Approval


#2210052

Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2210052
Expiry date:
31/10/2027
Size:
¾” BSP (F)
Marking:
KERS logo, model name, capacity, max pressure, max temp and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Model:
KERS OA - W230 KERS MVHR - W230 KERS MVHR - W200 SL KERS OA -W200 SL KERS MVHR - W160 KERS OA - W160
Factor:
KERS INNOVATION UK LTD
Company Name
KERS INNOVATION UK LTD
Address
Unit 3 ALBERT STREET, HOLLINWOOD, OLDHAM, OL8 3QPCompany

View All Listings by this Company

Print This Approval


#2211041

Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2211041
Expiry date:
30/11/2027
Size:
22mm Compression on all circuits
Marking:
EVOCyle logo, max pressure, max temp, capacity and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Model:
TTAMVD-0150LFB ThermaQ Evocyl Air 150 Direct TTAMVD-0180LFC ThermaQ Evocyl Air 180 Direct TTAMVD-0210LFC ThermaQ Evocyl Air 210 Direct TTAMVD-0250LFC ThermaQ Evocyl Air 250 Direct TTAMVD-0300LFC ThermaQ Evocyl Air 300 Direct TTAMVI-0150LFB ThermaQ Evocyl Air 150 Indirect TTAMVI-0180LFC ThermaQ Evocyl Air 180 Indirect TTAMVI-0210LFC ThermaQ Evocyl Air 210 Indirect TTAMVI-0250LFC ThermaQ Evocyl Air 250 Indirect TTAMVI-0300LFC ThermaQ Evocyl Air 300 Indirect
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2210057

Range of stainless steel indirect (single or twin coil), direct and heat pump unvented hot water storage cylinders. The heat pump models also incorporate a plate heat exchanger and a circulation pump. The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@90.0˚C. The products are supplied with an inlet control group consisting of an adjustable pressure reducing valve, adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 bar, a strainer, am expansion relief valve set at 6.0 bar and an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The products are also supplied with an immersion heater, an expansion vessel (12, 19 or 24 litres depending on model) and a tundish. Maximum supply pressure to the inlet control group: 16.0 bar. Maximum working pressure: Secondary circuit: 5.5 Bar. Primary Circuit: 6.0 Bar (All models except for the Direct - DI prefix models). Maximum operating temperature 75°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2210057
Expiry date:
31/10/2027
Note:
R008 only applies to the HP prefix (Heat Pump) models. Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression or 28mm stub (Heat Pump models only).
Marking:
WARMFLOW logo, capacity, model name, maximum pressure, maximum temperature, date of manufacture (month/YYYY) and other technical info on adhesive label on body.
Installation Requirements:
R001 R008 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
DI110UV - Direct Unvented water cylinder, DI140UV - Direct Unvented water cylinder, DI170UV - Direct Unvented water cylinder, DI200UV - Direct Unvented water cylinder, DI240UV - Direct Unvented water cylinder, DI290UV - Direct Unvented water cylinder. IN110UV - Indirect Unvented water cylinder, IN140UV - Indirect Unvented water cylinder, IN170UV - Indirect Unvented water cylinder, IN200UV - Indirect Unvented water cylinder, IN240UV - Indirect Unvented water cylinder, IN290UV - Indirect Unvented water cylinder. C140UV - Indirect Unvented water cylinder, C170UV - Indirect Unvented water cylinder, C200UV - Indirect Unvented water cylinder. TW170UV - Twin coil indirect Unvented water cylinder, TW200UV - Twin coil indirect Unvented water cylinder, TW240UV - Twin coil indirect Unvented water cylinder, TW290UV - Twin coil indirect Unvented water cylinder. HP170UV - Heat pump indirect unvented water cylinder, HP200UV - Heat pump indirect unvented water cylinder, HP240UV - Heat pump indirect unvented water cylinder, HP290UV - Heat pump indirect unvented water cylinder.
Manufacturer:
Warmflow Engineering Co. Ltd
Company Name
Warmflow Engineering Co. Ltd
Address
Lissue Industrial Estate, Moira Road, Lisburn Northern Ireland
Phone
02892 62 1515

View All Listings by this Company

Print This Approval


#2301036

Range of stainless steel indirect unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 90°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit: 5.5 Bar Primary circuit: 3.0 Bar Solar circuit: 3.0 Bar

Non-metallic materials and components comply with BS6920 at 80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2301036
Expiry date:
31/01/2028
Size:
Secondary circuit: 22mm compression. Primary circuit: 28mm compression. Solar circuit: 22mm compression
Marking:
World Heat, model no., serial no., capacity, Max working pressure, expansion vessel pressure, all on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Model:
120ECOSLIMSS 150ECOSLIMSS 180ECOSLIMSS 210ECOSLIMSS 120ECOSLIMSOLSS 150ECOSLIMSOLSS 180ECOSLIMSOLSS 210ECOSLIMSOLSS 120TCSSFLOWSLIM 150TCSSFLOWSLIM 180TCSSFLOWSLIM 210TCSSFLOWSLIM 120DSSFLOWSLIM 150DSSFLOWSLIM 180DSSFLOWSLIM 210DSSFLOWSLIM 120ISSFLOWSLIM 150ISSFLOWSLIM 180ISSFLOWSLIM 210ISSFLOWSLIM
Manufacturer:
World heat Ltd
Company Name
World heat Ltd

View All Listings by this Company

Print This Approval


#2303040

Range of indirect unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 6.0 bar Secondary: 5.5 bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2303040
Expiry date:
31/03/2028
Size:
Primary: 22mm Compression Secondary: 22mm compression
Marking:
Joule, Model name, capacity, max pressures, max temps and other technical information on label on body
Installation Requirements:
R001 R140 R360
Model:
TUMA-00150-LFC TUMA-00180-LFC TUMA-00210-LFC
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2103039

'Hurricane' range of Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103039
Expiry date:
31/03/2026
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Hurricane, Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Model:
HURIXXX - Hurricane indirect single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX/S - Hurricane indirect twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX - Hurricane direct electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L
Factor:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval


#2305339

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2305339
Expiry date:
31/05/2028
Size:
28mm compression.
Marking:
Manufacturers name, address, date of manufacturer, capacity, model no, serial no, pressure and technical information.
Installation Requirements:
R001 R140 R360 R511 R530
Model:
IDEPLUHP150PPSZ & IDEPLUHP180PPSZ: 550mm diameter; 150, 180; litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Single zone. IDEPLUHP150PPSZSL & IDEPLUHP180PPSZSL: 475mm diameter; 150, 180, litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP210PPDZ, IDEPLUHP250PPDZ & IDEPLUHP300PPDZ: 550mm diameter; 210, 250, 300 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP210PPDZSL: 475mm diameter; 210 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP180DUOPPSZ & IDEPLUHP210DUOPPSZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP250DUOPPSZ & IDEPLUHP300DUOPPSZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP180DUOPPDZ & IDEPLUHP210DUOPPDZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP250DUOPPDZ & IDEPLUHP300DUOPPDZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP400: 630mm diameter; 400 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14 kW. IDEPLU090MB: 630mm diameter; 90 litre; buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; and any cylinder without a buffer.
Factor:
Ideal Heating
Company Name
Ideal Heating
Address
National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom

View All Listings by this Company

Print This Approval


#2310324

Air Source Hot Water Cylinder range of cased and insulated, unvented hot water storage cylinders (enamelled steel) of the package type incorporating heat pump module. The DHW circuit includes a factory fitted temperature & pressure relief valve (Caleffi) set at 7 bar and 95˚C . The safety kit incorporates a pressure reducing valve (Caleffi) set at 3.5 bar, strainer, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2 and an expansion valve (Caleffi) set at 6 bar, expansion vessel (Reflex) and a tundish (Caleffi). The temperature of the hot water is controlled by a factory fitted manual control (set at 60˚C) and a high pressure switch positioned on the heat pump module (maximum temperature 65˚C) The cylinders are factory fitted with standard dual control immersion heater.Immersion heater incorporate control and manual resetting thermostats (maximum 89˚C). Maximum working pressure 5.5 Bar & maximum operating temperature 75°C. Maximum supply pressure to the pressure reducing valve is 12 bar. Maximum working pressure of the primary circuit 3.5 bar.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2310324
Expiry date:
31/10/2028
Size:
¾” BSP (F) ¾” BSP (M) connections provided.
Marking:
Curv printed on body. Curv, model, pressure ratings, volume and other tech info on adhesive label.
Installation Requirements:
R001 R140
Model:
HP80M5, HP110M5, HP150M5, HP200M3, HP250M3.
Factor:
Curv 360 Ltd
Company Name
Curv 360 Ltd
Address
Unit 1 Lakes Court Newborough Road Burton-On-Trent
Postcode
DE13 9PD
Country
United Kingdom
Phone
07572 066 618
General Email
john.bell@projectcurv.co.uk

View All Listings by this Company

Print This Approval


#240202703

Range of indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and an approved check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 3.0 Bar Secondary: 5.5 Bar Solar: 3.0 bar Maximum operating temperature 90.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
240202703
Expiry date:
28/02/2029
Size:
Primary circuit: 28mm compression Secondary circuit: 22mm compression Solar circuit: 22mm compression
Marking:
World Heat Ltd logo, model number, capacity, temperature and pressure and other technical information on adhesive label on cylinder.
Installation Requirements:
R001 R140 R360
Model:
120CLIMACYLSS2 – 120 Litre 550mm diameter with heat pump coil DN25 x 14M 150CLIMACYLSS2 – 150 Litre 550mm diameter with heat pump coil DN25 x 14M 180CLIMACYLSS3 – 180 Litre 550mm diameter with heat pump coil DN25 x 14M 210CLIMACYLSS3 – 210 Litre 550mm diameter with heat pump coil DN32 x 13M 250CLIMACYLSS3 – 250 Litre 550mm diameter with heat pump coil DN32 x 13M 300CLIMACYLSS3 – 300 Litre 550mm diameter with heat pump coil DN32 x 13M 120CLIMACYLSSTC12 – 120L 550mm diameter with heat pump & solar coils DN25 x 14M & DN20 x 7M 150CLIMACYLSSTC12 – 150L 550mm diameter with heat pump and solar coils DN25 x 14M & DN20 x 7M 180CLIMACYLSSTC13 – 180L 550mm diameter with heat pump and solar coils DN25 x 14M & DN20 x 7M 210CLIMACYLSSTC13 – 210L 550mm diameter with heat pump and solar coils DN32 x 13M 250CLIMACYLSSTC13 – 250L 550mm diameter with heat pump and solar coils DN32 x 13M 300CLIMACYLSSTC13 – 300L 550mm diameter with heat pump and solar coils DN32 x 13M 120TCSFLOW – 120L 550mm diameter with boiler and solar coils 2 x DN20 x 7M 150TCSFLOW – 150L 550mm diameter with boiler and solar coils DN20 x 8M & DN20 x 7M 180TCSFLOW – 180L 550mm diameter with boiler and solar coils DN20 x 8M & DN20 x 7M 210TCSFLOW – 210L 550mm diameter with boiler and solar coils DN25 x 10M & DN20 x 7M 250TCSFLOW – 250L 550mm diameter with boiler and solar coils DN25 x 10M & DN20 x 7M 300TCSFLOW – 300L 550mm diameter with boiler and solar coils DN25 x 14M & DN20 x 7M 120DSSFLOW – 120L 550mm diameter direct with no coils and 2 x immersion heaters 150DSSFLOW – 150L 550mm diameter direct with no coils and 2 x immersion heaters 180DSSFLOW – 180L 550mm diameter direct with no coils and 2 x immersion heaters 210DSSFLOW – 210L 550mm diameter direct with no coils and 2 x immersion heaters 250DSSFLOW – 250L 550mm diameter direct with no coils and 2 x immersion heaters 300DSSFLOW – 300L 550mm diameter direct with no coils and 2 x immersion heaters 120ISSFLOW – 120L 550mm diameter with boiler coil DN20 x 7M 150ISSFLOW – 150L 550mm diameter with boiler coil DN20 x 8M 180ISSFLOW – 180L 550mm diameter with boiler coil DN20 x 8M 210ISSFLOW – 210L 550mm diameter with boiler coil DN25 x 10M 250ISSFLOW – 250L 550mm diameter with boiler coil DN25 x 10M 300ISSFLOW – 300L 550mm diameter with boiler coil DN25 x 14M
Manufacturer:
World heat Ltd
Company Name
World heat Ltd

View All Listings by this Company

Print This Approval


#2312325

Range of cased and insulated stainless steel unvented water storage heaters. The DHW circuit includes a factory fitted combined temperature and pressure relief valve set at 6.0 bar and 90˚C. The product can be supplied with two possible safety kits (inlet control groups). One includes a pressure reducing valve adjustable between 1.5-6.0 bar, (but set at 3.0 bar), a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a pressure relief valve pre-set at 4.5 bar. The other includes a pressure reducing valve pre-set at 3.0 bar, an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection, and a pressure relief valve pre-set at 4.5 bar. The product is also supplied with an expansion vessel and a tundish. The compression connection of each inlet control group is for use with the following pipes: Both for use with copper pipe (manufactured to BS EN 1057). The inlet control group without an adjustable pressure reducing valve can also be used with PB pipe (with inserts) (manufactured to BS EN 7291-2:2010) and PEX pipe (with inserts) (manufactured to BS EN 7291-3:2010). Maximum supply pressure to inlet control group pressure reducing valve: 16.0 bar. Maximum working pressure 4.0 bar. Maximum operating temperature 99°C. Cold supply only.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2312325
Expiry date:
31/12/2028
Note:
Expansion vessels should be installed in the vertical orientation and located so as to minimise the length of any connecting pipework. R150 applies to the inlet group without an adjustable pressure reducing valve.
Size:
See model (capacity). 22mm compression (to inlet control group).
Marking:
Atlantic, address, pressure rating, serial number, capacity, and other technical information on adhesive label on body.
Installation Requirements:
R001 R140 R150 R360 R511
Model:
876509 - ATL CV4 STAINLESS STEEL FS 172L, 886123 - ATL CV4 STAINLESS STEEL FS 210L.
Factor:
Groupe Atlantic
Company Name
Groupe Atlantic
Address
Ideal Heating National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Country
United Kingdom
Phone
01482 492251

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.