Section Code 1800 : Pillar tap(s).
Back To Directory SectionsRange of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc (VL103 + VL103-5) or non-rising spindle headworks (all other models) with various operating members and metal backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps with brass bodies, (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model). The spout outlet of the F5117** model incorporates a plastic aerator. The spout outlet of the F5197**, F6007**, F6008** & F6117C** models incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps with brass bodies, (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model). The spout outlet of the F5198** & F6118C** models incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate plastic aerators (except 2.1977.005 that has flow restrictor) and the products are supplied with plastic backnuts. Maximum operating pressure 5 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps, (chrome plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a flow straightener. Maximum working pressure 10 bar. Maximum operating temperature 45 C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc (SL-T40608W) and single lever operating member or non-rising spindle headworks (all other models) with dome or cross top operating members and metal backnuts. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 Bar. Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass), incorporating non-rising spindle headworks with various operating members (see model). The spout outlets incorporate a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. BS6920 65°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc (VL102 & POR102) and single lever operating member or non-rising spindle headworks (all other models) with dome or cross top operating members and metal back nuts. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 Bar. Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps, (chrome plated brass bodies), incorporating quarter turn cermic disc headworks and single lever operating members. The products include metal back nuts. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps, (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members and plastic flow straighteners. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Range of pillar taps, (chrome plated brass bodies) incorporating non-rising spindle headworks with dome or cross-top type operating members. Models (VAL2 HNK C CD & VAL2 HNK C 6 CD) incorporate quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps, (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates plastic flow straighteners. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Pillar tap, (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporates plastic flow straighteners. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Range of pillar taps (chromium plated brass), incorporating ¼ turn ceramic disc headworks with a single lever operating member. The inlets incorporate a plastic flow regulator. The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members (SL-T30) or non-rising spindle headworks with cross top operating members (SL-T40). The spout outlet incorporates a plastic aerator (SL-T30) or a flow straightener (SL-T40407). The products are supplied with metal back-nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members (SL-T30) or non-rising spindle headworks with cross top operating members (SL-T40). The spout outlet incorporates a plastic aerator (SL-T30708X) or a flow straightener (SL-T40408). The products are supplied with metal back-nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of deck mounted self-closing pillar taps (chromium plated brass), incorporating a spring-loaded headwork with a dome type operating member. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal back-nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of pillar taps, (chrome plated brass bodies) incorporating non-rising spindle headworks with dome or cross-top type operating members. Model (C58118) incorporate quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pillar tap with (brass body - various finishes) incorporating a quarter turn ceramic disc headwork situated on the spout outlet with a cylinder type operating member. The spout outlet incorporates a plastic spray disc and a flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar, Maximum operating temperature 65°C.
Range of pillar tap (chrome plated brass), incorporating quarter ceramic disc headworks with single lever or dome type operating members. The spout outlets incorporate plastic aerators. Products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Pillar tap (chromium plated brass), incorporating quarter turn ceramic disc with single lever operating members and metal backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome type operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of bath pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and cross top operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 10 Bar. Maximum operating temperature 60°C.
Basin pillar tap (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straighteners. The products are supplied with metal backnuts. Models (VAL2 ½ E4 C CD & VAL2 ½ E6 C CD) are supplied with optional aerators that incorporate flow regulators. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar, Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar, Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.
Range of pillar taps, (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with cross top operating members. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass),incorporating either a non-rising spindle headworks (T6317 only) or a 1/4 turn ceramic disc (all other models) with either dome type, single lever or cross top operating members (see models) and metal backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure; 10 Bar Maximum operating temperature 60°C
Range of pillar taps (chrome plated brass bodies), incorporating either a non-rising spindle headworks (T6308 & T6307M only) or quarter turn ceramic disc headworks (all other models) with single lever, dome type or cross top type operating members (see models). The products are supplied with metal back nuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure; 10 Bar Maximum operating temperature 60°C
Range of pillar taps incorporating a quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar, Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straighteners. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrorme plated brass) with ¼ turn ceramic disc headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrorme plated brass) with ¼ turn ceramic disc headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated or matte black brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated or matte black brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass) incorporating quarter turn ceramic disc headworks with cross-top operating members. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with cross top operating members. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with cross top operating members. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps, (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork with a cross top operating member. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of pillar taps with (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork with a single lever or cross top operating member. The product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Page 3 of 4
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.