Taps
Section Code 1780 : Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing.
b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either:
a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or
b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or
c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or
d. Is legally installed in any premises.
Back To Directory Sections
WRAS Approval Number: #1912030
Range of wall mounted hose union taps (various body materials) incorporating a non-rising spindle headwork with a butterfly handle operating member. The 13.20252.G15.CP5R-8510 model also incorporates a lockshield device at the base of the operating stem. The spout outlets incorporate a hose union connector.
Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
- Section:
- 1780 Taps
- Section Subtitle:
- Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing.
b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either:
a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or
b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or
c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or
d. Is legally installed in any premises.
- WRAS Approval Number:
- 1912030
- Expiry date:
- 31/12/2024
- Size:
- ½” BSP (M)
- Marking:
- V&G, WRAS and size on body.
DR mark on DZR brass body models.
- Installation Requirements:
- R001 R040
- Model:
-
13.20202.G15.CP03-8510 (chrome plated brass).
13.20202.G15.CP5R (natural brass).
13.20202.G15.CP5R-8511(natural DZR brass).
13.20252.G15.CP5R-8510 (natural brass).
- Manufacturer:
- Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone,
Yuhuan,
Zhejiang
Country
China
View All Listings by this Company
WRAS Approval Number: #1912070
Range of wall mounted hose union taps (various body materials) incorporating a non-rising spindle headwork with a butterfly handle operating member. The spout outlets incorporate a hose union connector.
Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
- Section:
- 1780 Taps
- Section Subtitle:
- Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing.
b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either:
a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or
b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or
c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or
d. Is legally installed in any premises.
- WRAS Approval Number:
- 1912070
- Expiry date:
- 31/12/2024
- Size:
- ½” BSP (M)
- Marking:
- TS, SIZE, BATCH CODE, EN1213 7 V ON BODY
- Installation Requirements:
- R001 R040
- Model:
-
60635 (natural brass).
- Factor:
- TOOLSTATION LTD
Company Name
TOOLSTATION LTD
Address
EXPRESS PARK
BRISTOL ROAD
BRIDGEWATER
Postcode
TA6 4RN
Country
SOMERSET
View All Listings by this Company
WRAS Approval Number: #1912071
Range of wall mounted hose union taps (various body materials) incorporating a non-rising spindle headwork with a butterfly handle operating member. The spout outlets incorporate a hose union connector.
Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
- Section:
- 1780 Taps
- Section Subtitle:
- Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing.
b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either:
a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or
b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or
c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or
d. Is legally installed in any premises.
- WRAS Approval Number:
- 1912071
- Expiry date:
- 31/12/2024
- Size:
- ½” BSP (M)
- Marking:
- TPK, DATE OF MANUFACTURE MM/YY, EN1213 & SIZE ON BODY
- Installation Requirements:
- R001 R040
- Model:
-
1/2 270 WARRIOR (natural brass).
- Factor:
- BSS Industrial
Company Name
BSS Industrial
Address
BOSS Court
7 Barton Close
Postcode
LE19 1SJ
Country
Grove Park
Phone
01162 623232
Telex: 342761
View All Listings by this Company
WRAS Approval Number: #2104051
Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member.
Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
- Section:
- 1780 Taps
- Section Subtitle:
- Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing.
b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either:
a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or
b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or
c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or
d. Is legally installed in any premises.
- WRAS Approval Number:
- 2104051
- Expiry date:
- 30/04/2026
- Size:
- ¾” BSP male inlet x 19mmØ hose outlet
- Marking:
- V&G, WRAS and size on body.
Model 13.20202.G20.CP5R-8511 also has ‘DR’ on body.
- Installation Requirements:
- R001 R040
- Model:
-
13.20202.G20.CP03-8510.
13.20202.G20.CP5R-8510.
13.20202.G20.CP5R-8511.
- Manufacturer:
- Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone,
Yuhuan,
Zhejiang
Country
China
View All Listings by this Company
WRAS Approval Number: #2104064
Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member.
Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
- Section:
- 1780 Taps
- Section Subtitle:
- Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing.
b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either:
a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or
b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or
c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or
d. Is legally installed in any premises.
- WRAS Approval Number:
- 2104064
- Expiry date:
- 30/04/2026
- Size:
- ¾” BSP male inlet x 19mmØ hose outlet
- Marking:
- CPS and size on body.
- Installation Requirements:
- R001 R040
- Model:
-
961136
- Factor:
- CITY PLUMBING SUPPLIES HOLDINGS
Company Name
CITY PLUMBING SUPPLIES HOLDINGS
Postcode
NN6 7SL
View All Listings by this Company
Back To Directory Sections Page 1 of 4