Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#1905007

EMAS range of combination boilers with instant hot water and central heating system with a stainless-steel plate heat exchanger. Hot water is produced via heat from a centralised heating system (not supplied). The unit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel on the central heating circuit. The inlet and outlet of the primary and secondary circuits fitted with isolation valves. Maximum working pressure: primary circuit 2.5 bar & secondary circuit 10.0 bar. Maximum operating temperature: primary circuit 70˚C & secondary circuit 50˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1905007
Expiry date:
31/05/2024
Size:
Primary: ¾” BSP (M) inlet and outlet. Secondary: ½” BSP (M) inlet and outlet.
Marking:
E.C.A (manufacturer’s brand), model and technical information on adhesive label on side of boiler. E.C.A logo on front of boiler.
Installation Requirements:
R001 R360
Model:
Proteus Premix 24 HM Proteus Premix 28 HM Proteus Premix 30 HM Proteus Premix 35 HM
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Organize Sanayi Bolgasi 3 Kisim Mustafa Kemal Bulvari N013 Turkey

View All Listings by this Company

Print This Approval


#1906341

Range of wall mounted gas fired combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. Maximum working pressure 3.0 bar (primary) and 8.0 bar (secondary). Maximum operating temperature 90°C. Cold water supply only

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1906341
Expiry date:
30/06/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. No safety valve for the primary circuit is included with this product
Size:
15mm copper tails (secondary). 22mm copper tails (primary).
Marking:
Daikin, address, model No., pin No. and year of manufacture (YYYY) on data plate on base of boiler
Installation Requirements:
R001 R140 R360
Model:
EHY2KOMB28AA, EHY2KOMB32AA
Factor:
Daikin Europe NV.
Company Name
Daikin Europe NV.
Address
Zandvoordestraat 300, 8400 Oostende, Belgium

View All Listings by this Company

Print This Approval


#1907322

Range of gas fired instantaneous condensing domestic hot water heaters with integral storage tank. Having a stainless-steel coil and built in circulating pump. Maximum working pressure 11.0 bar. Maximum operating temperature 80°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1907322
Expiry date:
31/07/2024
Size:
1½” BSP (M)
Marking:
Cosmogas on front casing. Cosmogas, production date (YYYY) and other technical information on adhesive label on side of body
Installation Requirements:
R001 R140
Model:
Aguaplus 60, 70, 100, 115, 140
Manufacturer:
Cosmogas Srl
Company Name
Cosmogas Srl
Address

View All Listings by this Company

Print This Approval


#1909008

Range of wall mounted, gas fired combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The secondary circuit incorporates a strainer and plastic flow regulator. The boilers are supplied with straight spherical valves. Maximum working pressure of primary circuit is 2.5 bar and of secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 85°C and of secondary circuit is 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1909008
Expiry date:
30/09/2024
Size:
Primary circuit: 22mm compression inlet and outlet (to spherical valves). Secondary circuit: 15mm compression inlet and outlet (to spherical valves).
Marking:
Ravenheat on front cover.
Installation Requirements:
R001 R360
Proviso:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the water supply (Water Fittings) Regulations 1999.
Model:
Brand model prefix CSI Type boiler ref.: 85 AAA(T) 780 series, 120 (T), 150 (T). Brand model prefix CS or WH Type boiler ref.: 80(T) & 90 (T). Brand model prefix HE Type boiler ref.: 32, 42, 25ErP, 80ErP, 90ErP, 98ErP, 25C, 30C, 35C, 40C, 80, 98, 80S, 98S, 120S, 140S, BP31 HE. HE 25 C, HE 80 S, HE 80 S Compact, HE 25 S Compact, HE 25 C Compact, HE 25 CN Compact, HE 30 C, HE 98 S, HE 98 S Compact, HE 30 S Compact, HE 30 C Compact, HE 30 CN Compact, HE 35 C, HE 120 S, HE 120 S Compact, HE 35 S Compact, HE 35 C Compact, HE 35 CN Compact, HE 40 C, HE 140 S, HE 140 S Compact , HE 40 S Compact, HE 40 C Compact, HE 40 CN Compact. Brand model prefix HE System or CN System Type boiler ref.: 25C, 30C, 35C, 40C, 80S, 98S, 120S, 140S, 3,20ErP, 4,24ErP. HE 80 S System, HE 25 C Compact System, HE 25 S Compact System, HE 80 S Compact System, HE 80 CN Compact System, HE 98 S System, HE 30 C Compact System, HE 30 S Compact System, HE 98 S Compact System , HE 98 CN Compact System, HE 120 S System, HE 35 C Compact System, HE 35 S Compact System, HE 120 S Compact System, HE 120 CN Compact System, HE 140 S System , HE 40 C Compact System, HE 40 S Compact System, HE 140 S Compact System, HE 140 CN Compact System. Brand model prefix CS or WH Type boiler ref.: 3,20 & 4,24. Brand model prefix CSI Type boiler ref.: Primary & Primary Low Nox. Brand model prefix HE Regular Type boiler ref.: 3,20ErP & 4,24ErP.
Factor:
Ravenheat Manufacturing Ltd
Company Name
Ravenheat Manufacturing Ltd
Address
Chartists Way Leeds
Postcode
LS27 8JR
Phone
Tel: 01132 527007

View All Listings by this Company
Manufacturer:
Ravenheat International Srl.
Company Name
Ravenheat International Srl.
Address
Via Dell Agricolture, 50 Zevio (Verona) Italy

View All Listings by this Company

Print This Approval


#1910338

Electronically controlled Heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve, in line single check valve assembly, (suitable for backflow protection against Fluid Category 2) and and water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop comprising of an in-line double check valve assembly (suitable for backflow protection against Fluid Category 3), which incorporates an isolation valve, a stainless-steel braided EPDM lined flexible hose assembly. The inlet and outlet of all circuits incorporates a lever operated spherical valves with brass bodies. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 90˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
1910338
Expiry date:
31/10/2024
Note:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
¾” BSP (F) inlet/outlet on all circuits.
Marking:
Vtherm on front.
Installation Requirements:
R001
Model:
Vital Energi vTherm
Factor:
Vital Energi Utilities Limited
Company Name
Vital Energi Utilities Limited
Address
Century House Roman Road Blackburn
Postcode
BB1 2LD
Country
Lancashire
Phone
01254 296000
General Email
sales@vitalenergi.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 8

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.