Back To Directory SectionsRange of plate heat exchangers with pressed stainless steel plate bodies and copper brazing. Available with threaded or flat face seal connection (see model). Maximum working pressure varies by model: ZT190 & ZT207 - 8.0 bar; ZB190, ZB195, ZB200, ZB207 & ZB315 - 10.0 bar; ZC315 (flat face seal version only) - 16.0 bar; ZC190, ZC207, ZC315 (threaded only) & Z(B-C-E) 250, 400, 450, 500 – 30.0 bar or 45.0 bar (models with additional upper and lower plates only); ZB600 & ZB700 - 30.0 bar. Maximum operating temperature 99°C.
‘Fortes Aquaheat 540’ range of heat interface units (HIU) with twin stainless steel copper brazed plate heat exchangers providing space heating and instantaneous hot water. The hot water is generated via a plate heat exchanger. The cold inlet supply to the plate heat exchanger incorporates an in line single check valve assembly, (suitable for backflow protection against Fluid Category 2). The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 2.5 bar). The product is supplied with a filling loop comprising of an in-line double check valve assembly which incorporates an isolation valve (suitable for backflow protection against Fluid Category 3), a stainless steel braided EPDM lined flexible hose assembly and a separate isolation valve. The inlet and outlet of all circuits incorporates a lever operated spherical valve with a brushed chromium plated brass body. Maximum working pressures and operating temperatures: Primary (district heating): 16.0 bar and 100˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.0 bar and 95˚C.
Brass bodied heat exchanger assembly with copper tubes incorporating a heating and cooling circuit and an electrically operated fan with and external electrical control box. Maximum working pressure 16 bar. Maximum operating temperature 90°C
Heat interface unit providing indirect central heating (space heating) and instantaneous hot water via a district heating heat input circuit. The connection to the water supply incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The hot water and central heating is generated via a plate heat exchanger by the use of district heating. The space heating circuit incorporates an expansion vessel and an expansion relief valve (3.0 bar). Maximum working pressures: District heating circuit 16.0 bar. Central heating Circuit 2.5 bar. Domestic hot water 10.0 bar. Maximum operating temperature 85°C.
Range of copper brazed, stainless steel heat exchangers. E8LAS models are available with between 10 & 70 plates. All other models are available with between 10 & 40 plates. EB6T models have a maximum working pressure of 10.0 bar. All other models 16.0 bar. Maximum operating temperature 99°C.
Range of pre-assembled hydraulic blocks incorporating a plate heat exchanger, pressure relief valve set at 3.0 bar and circulation pump. Maximum working pressure: primary 2.5 bar. Maximum working pressure: secondary 10.0 bar. Maximum operating temperature 80°C.
Hydraulic block incorporating heat exchangers with pressed stainless-steel plate bodies and copper brazing. Product also incorporates primary and secondary water way with PPS plastic fittings and adaptors and a flow adjustment valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC
Range of heat interface units providing heating and instantaneous hot water. The central heating and hot water is generated via plate heat exchangers. The central heating circuit contains a pressure relief valve (3.0 bar). Maximum working pressure primary circuit: 2.5. bar. Maximum working pressure district heating: 16.0 bar. Maximum working pressure secondary hot water circuit 10.0 bar. Maximum operating temperature 85°C.
Copper plate heat exchanger with copper connections, incorporating 72 fins. Maximum working pressure Heating circuit 3.0 bar, Sanitary circuit 8.0 bar Maximum operating temperature 99°C
Domestic hot water heat recovery unit incorporating a stainless steel plate heat exchanger. The product is supplied with two optional 15mm x 15mm compression 90° elbows for installation on the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Type "J" range of plate heat exchangers with stainless steel (AISI 304L) bodies and copper welding. Maximum working pressure 3.0 bar (Primary Circuit) and 10.0 bar (Secondary Circuit). Maximum operating temperature 80°C.
Range of modular combined heating interface units providing a combination of either hot water, heating or cooling via a plate heat exchanger depending on model options. Heating and cooling circuits incorporate a safety relief valve (set at 3 bar) and expansion vessel and inlet connection can be either top or bottom entry configuration. Maximum working pressure 16 bar (primary, CWS and HWS) 2.5 bar on heating circuit. Maximum operating temperature 85°C.
Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Range of copper brazed stainless-steel heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Page 1 of 3
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.