Fire Protection

Section Code 1070 : Products used within fire protection systems. Products listed in this section are for non-wholesome water use only.

Back To Directory Sections

#1904057

Automated fire sprinkler system, consisting of an in-line water filter, a solenoid valve (activated by Smartscan (IR Sensor) once alarm confirms a fire), a pump assembly, various connecting hoses, a quick connect fitting (with test port) and a spray head outlet. The product is also supplied with a non-verifiable single check valve assembly (suitable for backflow prevention up to Fluid Category 2), intended for installation at the inlet. Maximum working pressure: 10.0 Bar. Cold water use only.

Section:
1070 Fire Protection
Section Subtitle:
Products used within fire protection systems. Products listed in this section are for non-wholesome water use only.
WRAS Approval Number:
1904057
Expiry date:
30/04/2024
Note:
No hose is supplied for connection between the control unit and spray head outlet. The single check valve supplied with this product must be installed to maintain the validity of the WRAS approval. This product has been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. The decision of the Scheme to list them is not to be taken as any guide as to their effectiveness to do the job for which they have been designed.
Size:
¾” BSP (F)
Marking:
Automist on control unit. Plumis on adhesive label on control unit.
Installation Requirements:
R001 R040 R415
Model:
Automist SmartScan Hydra System.
Manufacturer:
Plumis Ltd
Company Name
Plumis Ltd
Address
HMS President (1918), Victoria Embankment, London
Postcode
EC4Y 0HJ
Phone
+44 (0) 208 133 8775

View All Listings by this Company

Print This Approval


#1907331

Range of pump systems for use in fixed installation fire sprinkler systems. Having black polymer coated cast iron bodies, pressure gauge and pressure switch and electronic controller installed within a cabinet. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1070 Fire Protection
Section Subtitle:
Products used within fire protection systems. Products listed in this section are for non-wholesome water use only.
WRAS Approval Number:
1907331
Expiry date:
31/07/2024
Note:
IRN R150 is required on the supply to this fitting because it is for a non-wholesome water application and the materials of construction have not been fully assessed against the requirements of the Regulations. Additional backflow protection may be required depending on the type of sprinkler system or arrangement this unit is employed within.
Size:
See model.
Marking:
Grundfos logo on front of casing. Grundfos logo, serial no, part no, date of manufacture YYWW and technical information on adhesive label on pump.
Installation Requirements:
R001 R150 R415
Model:
98916439 – 1” suction x 1” discharge 98916440 – 1” suction x 1” discharge 98916461 – 1¼” suction x 1” discharge 98916462 – 1¼” suction x 1” discharge 99282914 – 1¼” suction x 1” discharge 98916463 – 1½” suction x 1½” discharge 98916464 – 1½” suction x 1½” discharge All connections are BSP (F)
Manufacturer:
Grundfos Manufacturing Ltd.
Company Name
Grundfos Manufacturing Ltd.
Address
Ferryboat Lane Castletown Sunderland
Postcode
SR5 3JL
Phone
0191 549 5555

View All Listings by this Company

Print This Approval


#2310095

SD 200` pressure augmenting fire sprinkler device comprising of an end suction fire pump with a non-return valve on its outlet, multistage jockey pump with a lever operated spherical valve and non-return valve on its outlet, galvanised steel and copper pipework, pressure switches and gauges, pump sensing unit and two stainless steel braided EPDM lined hoses. Maximum working pressure 11.0 bar. Cold water use only.

Section:
1070 Fire Protection
Section Subtitle:
Products used within fire protection systems. Products listed in this section are for non-wholesome water use only.
WRAS Approval Number:
2310095
Expiry date:
31/10/2028
Note:
Additional backflow protection may be required depending on the category of risk of the fire sprinkler system.
Size:
Electric fire pump: DN100 flanged. Jockey pump: DN32 PJE.
Marking:
Triple P Products logo, SD200 and website on body.
Installation Requirements:
R001 R150 R415
Model:
SD200
Factor:
Triple P projects Ltd.
Company Name
Triple P projects Ltd.
Address
Old County Police Station, 15 Neath Road, Resolven
Postcode
SA11 4AA
Country
Neath

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.