Range of ultrasonic remote transmission water meters with stainless steel body. The products incorporate a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201). The inlets incorporate a spherical valve and a check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201). The inlet incorporates a stop valve. Model MB77025AM Matrix Single (CV) incorporates a single check valve cartridge and model MB77025DCV Matrix Dual (DCV) incorporates two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies. The inlets incorporate a stop valve. Model MB77025CG Matrix Single (CV) incorporates a single check valve cartridge and model MB77025CGDCV Matrix Dual (DCV) incorporates two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Self-closing hand spray with a stainless-steel body. The inlet incorporates a flow regulator and an approved check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5 bar. Max operating temperature 60°C.
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
A range of wall mounted shower handsets (brass bodies) incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection, and plastic flow regulators. The products are also supplied with shower hoses and handset holders. Maximum operating temperature 60.0°C Open outlet use only.
Range wall mounted shower outlet connectors with brass bodies, chrome finish. The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum operating pressure 10 Bar. Maximum operating temperature 70°C.
Shower handset with brass body (various finishes). Supplied with a shower hose and wall elbow. Handset inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: Open Outlet. Maximum operating pressure: 85oC.
Range of shower handsets and connection hoses (brass bodies – various finishes). The inlet incorporates an approved check valve cartridge (with plastic flow regulator) however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 60°C
Page 225 of 279
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.